Catalog Number 1012449-08
Device Problems Detachment Of Device Component (1104); Kinked (1339); Improper or Incorrect Procedure or Method (2017)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/09/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4). During processing of this complaint, attempts were made to obtain complete event, patient and device information. (b)(4). The device was received. Investigation is not yet complete. A follow up report will be submitted with all relevant information.
 
Event Description
It was reported the procedure was to treat a lesion with heavy tortuosity and heavy calcification in the mid right coronary artery (rca). The 3. 0x8mm nc trek balloon catheter was being loaded without resistance into the guiding catheter, and the proximal shaft kinked. In an attempt to straighten the proximal shaft, it separated in two pieces at the kink. A new nc trek balloon catheter was used to complete the procedure successfully. There was no adverse patient effect and no clinically significant delay in the procedure. No additional information was provided.
 
Manufacturer Narrative
(b)(4). Evaluation summary: visual inspection was performed on the returned device. The reported separation and kink were confirmed. It should be noted that the nc trek rx instruction for use states: do not use, or attempt to straighten, a catheter if the shaft has become bent or kinked; this may result in the shaft breaking. A review of the lot history record revealed no manufacturing nonconformities that would have contributed to this complaint. Additionally, a review of the complaint history identified no other similar incidents from this lot. The investigation determined the reported kink appears to be related to circumstances of the procedure; however, the shaft separation appears to be related to user error. There is no indication of a product quality issue with respects to the design, manufacture, or labeling of the device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameNC TREK CORONARY DILATATION CATHETER
Type of DeviceCORONARY DILATATION CATHETER
Manufacturer (Section D)
AV-TEMECULA-CT
abbott vascular
26531 ynez road
temecula CA 92591 4628
Manufacturer (Section G)
EL COYOL, COSTA RICA REG# 3009031392
abbott vascular
26531 ynez road
temecula CA 92591 4628
Manufacturer Contact
connie speck
abbott vascular
26531 ynez road
temecula, CA 92591-4628
9519143996
MDR Report Key6278010
MDR Text Key66011952
Report Number2024168-2017-00682
Device Sequence Number1
Product Code LOX
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K110134
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation
Remedial Action Other
Type of Report Initial,Followup
Report Date 02/20/2017
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received01/25/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date09/30/2019
Device Catalogue Number1012449-08
Device Lot Number61018G1
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer01/23/2017
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received02/13/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/01/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No