Model Number 33650014
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Necrosis (1971)
Event Date 03/09/2017
Event Type  Injury  
Manufacturer Narrative
Neither the device nor applicable imaging films were returned to the manufacturer for evaluation, therefore, the cause of the event cannot be determined.
 
Event Description
Allegedly, it was reported that the patient underwent a total ankle replacement surgery.Approximately four months post-op the patient underwent a revision due to avascular necrosis of the anterior aspect of the tibia.No additional patient complications were reported.
 
Manufacturer Narrative
Visual examination of the returned devices does not show any overall gross deformation.The poly was returned still seated on the tibial tray.Visual examination the porous surface of the talar dome and tibial tray does exhibit a few areas of apparent bone attachment.Radiographic images were provided, from review of the images it does appear that the tibial tray had subsided/loosened.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INFINITY®
Type of Device
PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER
Manufacturer (Section D)
WRIGHT MEDICAL TECHNOLOGY, INC.
11576 memphis arlington rd
arlington TN 38002
Manufacturer (Section G)
WRIGHT MEDICAL TECHNOLOGY, INC.
11576 memphis arlington rd
arlington TN 38002
Manufacturer Contact
timothy nickel
1023 cherry road
memphis, TN 38117
9014516318
MDR Report Key6456296
MDR Text Key71597326
Report Number1043534-2017-00036
Device Sequence Number1
Product Code HSN
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K140749
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 03/09/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/04/2017
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date02/21/2024
Device Model Number33650014
Device Lot Number1573348
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/11/2017
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Distributor Facility Aware Date03/09/2017
Event Location Hospital
Date Manufacturer Received03/09/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured02/01/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age62 YR
-
-