MAUDE Adverse Event Report: BARD PERIPHERAL VASCULAR, INC. ULTRAVERSE RX PTA DILATATION CATHETER PTA BALLOON DILATATION CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BARD PERIPHERAL VASCULAR, INC. ULTRAVERSE RX PTA DILATATION CATHETER PTA BALLOON DILATATION CATHETER Back to Search Results
Model Number U41501Q1HRX
Device Problems Peeled / Delaminated; Failure to Advance
Event Date 06/24/2016
Event Type  Malfunction  
Manufacturer Narrative

As a result of a retrospective review of events that occurred in japan and in accordance with 21 c. F. R. Part 803, this event was assessed and determined to be mdr reportable as a malfunction. No medical records or no medical images have been made available to the manufacturer; however, a photo has been provided. As the lot number for the device was provided, a review of the device history records is currently being performed. The device has not been returned to the manufacturer for evaluation. The investigation of the reported event is currently underway. The information provided by bard represents all of the known information at this time. Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.

 
Event Description

It was reported that during the treatment for chronic total occlusion (cto) with calcification in the left anterior tibial artery (ata) by an ipsilateral antegrade approach, approximately 20 cm of ribbon-like material of the pta catheter was allegedly found when it was removed from the patient. Before the catheter removal, the health care provider attempted to pass the catheter through the lesion but failed. No patient injury was reported.

 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameULTRAVERSE RX PTA DILATATION CATHETER
Type of DevicePTA BALLOON DILATATION CATHETER
Manufacturer (Section D)
BARD PERIPHERAL VASCULAR, INC.
1625 w 3rd st.
tempe AZ 85281
Manufacturer (Section G)
CLEARSTREAM TECHNOLOGIES LTD.
moyne upper
enniscorthy, co. wexford
EI 
Manufacturer Contact
judith ludwig
1625 w 3rd st.
tempe , AZ 85281
4803032689
MDR Report Key6556169
Report Number2020394-2017-00432
Device Sequence Number1
Product CodeLIT
Report Source Manufacturer
Source Type COMPANY REPRESENTATIVE,FOREIG
Reporter Occupation
Type of Report Initial,Followup
Report Date 07/13/2017
1 Device Was Involved in the Event
0 PatientS WERE Involved in the Event:
Date FDA Received05/09/2017
Is This An Adverse Event Report? No
Is This A Product Problem Report? Yes
Device Operator HEALTH PROFESSIONAL
Device EXPIRATION Date02/28/2018
Device MODEL NumberU41501Q1HRX
Device Catalogue NumberU41501Q1HRX
Device LOT Number50119441
Was Device Available For Evaluation? No
Is The Reporter A Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received07/11/2017
Was Device Evaluated By Manufacturer? Device Not Returned To Manufacturer
Date Device Manufactured02/03/2015
Is The Device Single Use? Yes
Is this a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-