• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COOK INC NCIRCLE TIPLESS STONE EXTRACTOR; FFL DISLODGER, STONE, BASKET, URETERAL, METAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK INC NCIRCLE TIPLESS STONE EXTRACTOR; FFL DISLODGER, STONE, BASKET, URETERAL, METAL Back to Search Results
Model Number N/A
Device Problems Device Operates Differently Than Expected (2913); Difficult to Open or Close (2921)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The event is currently under investigation.A follow-up report will be submitted upon receipt of additional information or completion of the investigation.
 
Event Description
It was reported that the physician was performing ureteroscopy and laser lithotripsy procedures on a patient by using the ncircle tipless stone extractor.The physician retracted the basket and found that four wires of the basket collapsed on each other and became a two wire basket and would not expand to its original four wire shape.The physician completed the procedure by using another ncircle tipless stone extractor device.No unintended section of the device remained inside the patient¿s body.The patient did not require an additional procedure due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.
 
Manufacturer Narrative
Investigation summary: a review of the documentation and quality control of the device were conducted during the investigation.No product was returned for product evaluation and no lot number was provided.Additionally, a document based investigation evaluation was not performed.There was no evidence to suggest the product was not made to specifications.A review of the device history record and reported complaints because no lot number was provided.Based on the information provided and the results of our investigation, a definitive root cause could not be reported or established at this time.The quality engineering risk assessment for this failure mode was reviewed and it was determined that no additional risk mitigating activity is required at this time.The appropriate personnel will be notified and we will continue to monitor for similar complaints.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NCIRCLE TIPLESS STONE EXTRACTOR
Type of Device
FFL DISLODGER, STONE, BASKET, URETERAL, METAL
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
Manufacturer Contact
larry pool
750 daniels way
bloomington, IN 47404
8123392235
MDR Report Key6728215
MDR Text Key80567980
Report Number1820334-2017-01709
Device Sequence Number1
Product Code FFL
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 01/17/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/20/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue NumberNTSE-022115-UDH
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received01/16/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-