MAUDE Adverse Event Report: CLEARSTREAM TECHNOLOGIES LTD. LIFESTREAM; BALLOON EXPANDABLE VASCULAR COVERED STENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CLEARSTREAM TECHNOLOGIES LTD. LIFESTREAM; BALLOON EXPANDABLE VASCULAR COVERED STENT Back to Search Results
Catalog Number LSM1350637
Device Problem Occlusion Within Device (1423)
Patient Problems Occlusion (1984); Claudication (2550)
Event Date 07/07/2017
Event Type  Injury  
Manufacturer Narrative
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.Receipt of device is not expected.The investigation is currently in progress.
 
Event Description
It was reported that there was restenosis.The complaint device was implanted (b)(6) 2015 and there were no anomalies or no failure with the device.The stent was implanted in the right external iliac artery.Another stent was also implanted in the left common iliac artery.The patient presented with increasing symptoms of claudication in both legs.There was suspected instent restenosis in left cia on (b)(6) 2017.The patient was admitted to hospital on (b)(6).Angiography showed occlusion of stents in left common iliac artery and right external iliac artery.A covered stent was used to treat the left cia and a bare stent was used to treat the right eia.The treatment was successful and there was sufficient outflow to the distal lower limb.The patient was discharged without sequelae.There was no patient injury reported.
 
Manufacturer Narrative
It was reported that there was restenosis.The complaint device was implanted (b)(6) 2015 and there were no anomalies or no failure with the device.The stent was implanted in the right external iliac artery.Another stent was also implanted in the left common iliac artery.The patient presented with increasing symptoms of claudication in both legs.There was suspected instent restenosis in left cia on (b)(6) 2017.The patient was admitted to hospital on (b)(6) july.Angiography showed occlusion of stents in left common iliac artery and right external iliac artery.A covered stent was used to treat the left cia and a bare stent was used to treat the right eia.The treatment was successful and there was sufficient outflow to the distal lower limb.The patient was discharged without sequelae.There was no patient injury reported.The lot history records have been reviewed with special attention to the manufacturing and inspection of this product.The device was found to have met specifications prior to shipment.No manufacturing anomalies were identified that may have caused or contributed to the reported event.This is the first reported complaint for this lot number and issue to date.The device was not returned for evaluation.The result of the investigation is inconclusive as the sample was not returned for evaluation.Based upon the available information a definitive root cause cannot be determined.It cannot be proven if the complaint stents triggered the restenosis.It is also unknown whether patient factors or procedural techniques contributed to the reported event.Based on analysis performed no additional action is required at this time.The ifu states: a device description: implant: the lifestream¿ balloon expandable vascular covered stent is comprised of an electropolished balloon-expandable stent made from 316l stainless steel, encapsulated between two layers of eptfe.Indication for use: the lifestream¿ balloon expandable vascular covered stent is indicated for the treatment of atherosclerotic lesions in common and external iliac arteries.Directions for use: site access and preparation: using standard techniques access the artery and place an introducer sheath or guiding catheter of appropriate inner diameter and a 0.035" (0.89 mm) guidewire across the target lesion.Perform diagnostic angiography to confirm site of implantation and measure the reference vessel diameter and lesion length.Covered stent size selection select a covered stent diameter that is approximately 5%-20% larger than the largest reference vessel diameter at the proximal or distal target site.Refer to the sizing table on the packaging label for appropriate selection of the covered stent diameter and length.Endovascular system preparation carefully remove the selected device from the package.Inspect the covered stent for adherence to the balloon and centered placement in relation to the balloon marker bands.If the covered stent is not centered and/or does not firmly adhere to the balloon, do not use.Flush the delivery system guidewire lumen with sterile saline mixture until saline drops from the distal end of the endovascular system.Air evacuation a 20 cc or smaller luer-lock syringe with a minimum of 5 cc¿s sterile saline mixture is recommended for use for aspirating this device.With the distal balloon tip pointing down and positioned below the level of the syringe, pull negative pressure until all air is expelled.Induce a negative pressure to remove any air from the balloon and inflation lumen.Repeat until all air is expelled.Carefully release to neutral.Allow the inflation lumen to fill with the diluted contrast medium and maintain a neutral pressure.Important: do not apply positive pressure to the balloon.Attach the prefilled inflation device to the inflation lumen of the catheter hub, ensuring no air bubbles remain at the catheter connection.Verify that the covered stent is still centered between the two radiopaque markers on the balloon catheter.Introduction of the endovascular system and placement of the covered stent advance the endovascular system over the guidewire into the introducer sheath.Further advance the endovascular system to the target treatment site within the introducer sheath and position the covered stent across the lesion.Verify that the covered stent is still centered within the balloon marker bands.Slowly retract the introducer sheath / guiding catheter while maintaining the position of the covered stent.Ensure the introducer sheath is retracted far enough to not compromise the balloon expansion and covered stent release.(b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LIFESTREAM
Type of Device
BALLOON EXPANDABLE VASCULAR COVERED STENT
Manufacturer (Section D)
CLEARSTREAM TECHNOLOGIES LTD.
moyne upper
enniscorthy, co. wexford
EI 
Manufacturer (Section G)
CLEARSTREAM TECHNOLOGIES LTD.
moyne upper
enniscorthy, co. wexford
EI  
Manufacturer Contact
fiona nimhullain
539237111
MDR Report Key6813786
MDR Text Key83463025
Report Number9616666-2017-00071
Device Sequence Number1
Product Code LIT
Combination Product (y/n)N
Reporter Country CodeGM
PMA/PMN Number
P160024
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other
Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date 10/05/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/23/2017
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date08/31/2017
Device Catalogue NumberLSM1350637
Device Lot Number50112184
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Event Location Hospital
Date Manufacturer Received08/16/2017
Date Device Manufactured09/08/2014
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-