Model Number QSR9161400
Device Problem Crack (1135)
Patient Problem No Code Available (3191)
Event Date 10/16/2017
Event Type  Injury  
Manufacturer Narrative
Without the benefit of examination and testing, coloplast is precluded from commenting on the condition of the device or the cause of the occurrence.Should additional facts prompt us to alter or supplement any information of conclusions contained in the original mdr or in any prior supplemental reports, a follow-up report will be submitted.
 
Event Description
According to the available information, there was a device tubing crack.
 
Manufacturer Narrative
This follow-up mdr is created to document the evaluation of the returned device.A titan otr pump and two cylinders were received for evaluation.Examination and testing of the returned components revealed a separation at the exhaust tube/strain relief junction of the longer exhaust tube of the pump.Testing revealed this to be a site of leakage.The separation appears to be rough and irregular, indicating sufficient stress was exerted.No functional abnormalities are noted with cylinder #1 or cylinder #2.Based on previous quality simulations and examination of the returned product, quality concluded that the rough and irregular surfaces associated with this separation indicates that sufficient stress(s) was exerted on the longer exhaust tube of the pump to separate the site while in-vivo.A separation of this type would then allow the loss of fluid, making the device inoperable.Management routinely reviews events such as this and monitors complaint levels.Additionally, events of this type are captured in the product risk documentation.Based on this information no further corrective action is required at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TITAN OTR SCROTAL 16CM
Type of Device
INFLATABLE PENILE PROSTHESIS
Manufacturer (Section D)
COLOPLAST A/S
holtedam 1
humlebaek, 3050
DA  3050
Manufacturer (Section G)
COLOPLAST MANUFACTURING US, LLC
1601 west river road north
minneapolis MN 55411
Manufacturer Contact
christine buckvold
1601 west river road north
minneapolis, MN 55411
6123024982
MDR Report Key6997198
MDR Text Key90898056
Report Number2125050-2017-00546
Device Sequence Number1
Product Code FHW
Combination Product (y/n)N
PMA/PMN Number
P000006
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Type of Report Initial,Followup
Report Date 01/08/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/02/2017
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Lay User/Patient
Device Model NumberQSR9161400
Device Catalogue NumberQSR9161400
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/23/2017
Was the Report Sent to FDA? No
Date Manufacturer Received10/16/2017
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age63 YR
-
-