INTUITIVE SURGICAL,INC. DA VINCI XI SURGICAL SYSTEM ENDOSCOPIC INSTRUMENT CONTROL SYSTEM Back to Search Results
Model Number IS4000 A70P7B
Device Problems Device Displays Incorrect Message (2591); Device Operates Differently Than Expected (2913)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 11/02/2017
Event Type  malfunction  
Manufacturer Narrative
Intuitive surgical, inc (isi) received the unit involved with this complaint and completed the device evaluation. Failure analysis verified the customer reported failure by installing the board on the test system. The system came up with the reported error in the log. This complaint is being reported due to a da vinci system malfunction rendering the da vinci system unavailable for use after the start of a surgical procedure. Although no patinet harm occurred, if this malfunction were to recur it could cause or contribute to an adverse event.
 
Event Description
It was reported that during a da vinci-assisted inguinal hernia repair procedure, the boom tapped something then it started faulting. The site rebooted the system and it started faulting with an error 319. The site made the decision to convert and complete the procedure using traditional laparoscopic techniques. There was no report of patient harm, adverse outcome or injury. An isi field service engineer (fse) was dispatched to the facility and was able to reproduce the reported failure. The 319 error was observed in the logs and moderate damage to the boom's back cover was noted. To resolve the issue, the fse replaced the axes controller platform (acp) board. The acp refers to the motor driver boards to drive the patient side cart (psc) and gantry motors.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameDA VINCI XI SURGICAL SYSTEM
Type of DeviceENDOSCOPIC INSTRUMENT CONTROL SYSTEM
Manufacturer (Section D)
INTUITIVE SURGICAL,INC.
sunnyvale CA
Manufacturer (Section G)
INTUITIVE SURGICAL, INC.,
950 kifer rd
sunnyvale CA
Manufacturer Contact
tabitha reed
950 kifer rd
sunnyvale, CA 
4085232420
MDR Report Key7065418
MDR Text Key93562262
Report Number2955842-2017-00796
Device Sequence Number1
Product Code NAY
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K131861
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other
Reporter Occupation
Type of Report Initial
Report Date 11/02/2017
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received11/28/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Model NumberIS4000 A70P7B
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/14/2017
Is the Reporter a Health Professional? No
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received11/02/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured07/01/2016
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse

-
-