Model Number N/A
Device Problems Bent (1059); Difficult to Insert (1316); Device Damaged by Another Device (2915)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 11/20/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Concomitant medical products: xl-115366, acrom xl 44-41 std hmrl brng, 145620.The 110017268, humeral bearing assembly tool, 12783-01.Product has been received by zimmer biomet and the investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event Description
It was reported that the ring of the humeral tray was bent by the humeral bearing insertion tool when trying to insert the bearing.The bearing would not seat properly.The surgeon noted that both the humeral tray and bearing were damaged.A new humeral tray and humeral ring were requested.Attempts have been made and additional information on the reported event is unavailable.
 
Manufacturer Narrative
Complaint sample was evaluated and the reported event was confirmed.Visual inspection of the returned product confirms that the ringloc is stuck in the humeral tray and damaged where it shows through the extraction slot.There is some damage to the bottom of the inserter tool exactly where it would contact the ring.The bearing shows some signs of damage exactly where the ringloc is stuck in the tray.The tray is visually conforming to the print.The locking ring was found to be dimensionally conforming.Device history record was reviewed and no discrepancies were found.Root cause was unable to be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COMP RVS TRAY CO 44MM
Type of Device
PROSTHESIS, SHOULDER
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
Manufacturer (Section G)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
Manufacturer Contact
christina arnt
56 e. bell dr.
warsaw, IN 46582
5745273773
MDR Report Key7128028
MDR Text Key95773738
Report Number0001825034-2017-11250
Device Sequence Number1
Product Code KWS
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
PK113069
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,health profession
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 03/22/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/19/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Physician
Device Model NumberN/A
Device Catalogue Number115370
Device Lot Number638530
Other Device ID Number(01) 0 0880304 54320 1
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/29/2017
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/19/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/25/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Removal/Correction NumberN/A
Patient Sequence Number1
-
-