SIEMENS MEDICAL SOLUTIONS USA, INC. ACUSON Z6MS ULTRASOUND TRANSDUCER; ULTRASOUND DEVICE Back to Search Results
Model Number Z6MS TRANSDUCER
Device Problem Bent (1059)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/20/2017
Event Type  malfunction  
Manufacturer Narrative
The device referenced in this report has not been returned to siemens for evaluation.If additional information is received or if the device is returned at a later date, this report will be supplemented.(b)(4).
 
Event Description
It was reported that after the patient was intubated, the physician had a difficult time maneuvering the transducer probe during a transesophageal echocardiography (tee) procedure.It was noted under fluoroscopy that there was a hard bend on the probe which was not seen before the procedure started.The physician pulled out the probe and then reintubated the patient with a different but similar transducer.The ultrasound system was also replaced to continue and complete the tee.There was no patient adverse event reported.No additional information was provided.
 
Manufacturer Narrative
This supplemental report is being submitted to correct the serial number of the device (see section d4); update the device available for evaluation (see section d10); provide the new date received by manufacturer (see section g4); provide the type of report (see section g7); provide the type of reportable event (see section h1); provide the type of follow-up (see section h2); update the device evaluated by manufacturer (see section h3); provide the device manufacture date (see section h4); update the event problem and evaluation codes (see section h6); and provide the device evaluation results (see section h10).The device referenced in this report was returned to siemens for investigation.Visual inspection of the transducer confirmed the reported issue.Investigation found that the monocoil was not attached to the lug in the articulation section of the transducer.The monocoil was observed to be dislocated and caused a kink or bend when guide tube is stress perpendicular to the force applied.The transducer was sent to the instrument technology inc.(iti) for further analysis.Multiple tests were done at iti and they reported that there could be multiple causes of the reported issue.However, since the monocoil damage likely occurred during the insertion process of the cable assembly (when the flex circuit was still the older larger version), iti concluded that the cause for the reported issue is due to the tight packing of the flex circuit which restricts motion inside the cable assembly.The flex circuit issue in the cable assembly is addressed by capa2017-11000337, where in the corrective action, the cable bundle diameter was decreased.Engineers stated that the flex/cable packaging could stress the part during insertion which can cause kinking and that the new flex/cable packaging (post-capa) has smaller outer diameter and will help prevent this type of failure.The cable assembly design changed with smaller cable bundle outer diameter since jul.2017.A review of the device history record (dhr) was performed and there is no information to indicate any non-conformance at the time of manufacturing process.Reference complaint # (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACUSON Z6MS ULTRASOUND TRANSDUCER
Type of Device
ULTRASOUND DEVICE
Manufacturer (Section D)
SIEMENS MEDICAL SOLUTIONS USA, INC.
685 east middlefield road
mountain view CA 94043 4050
MDR Report Key7160298
MDR Text Key96399375
Report Number3009498591-2018-00001
Device Sequence Number1
Product Code ITX
Combination Product (y/n)N
PMA/PMN Number
K142628
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,user f
Type of Report Initial,Followup
Report Date 06/28/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/03/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberZ6MS TRANSDUCER
Device Catalogue Number10436113
Device Lot NumberN/A
Was Device Available for Evaluation? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received06/25/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-