Model Number I7
Device Problems No Display/Image (1183); Display or Visual Feedback Problem (1184); Device Operates Differently Than Expected (2913)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/11/2017
Event Type  malfunction  
Manufacturer Narrative
Additional information: patient demographics provided. A medtronic representative reported that the issue occurred in an oblique lumbar interbody fusion (olif).
 
Manufacturer Narrative
Device code was corrected. If information is provided in the future, a supplemental report will be issued.
 
Manufacturer Narrative
Patient information was unavailable from the site. A medtronic representative inspected the navigation system onsite and confirmed the issue. The representative was able to identify the touch panel input (input #2) on the transceiver was related to the monitor presenting the problem. The transceiver touch panel input #2 had a fiber optic cable labeled channel 1 connected and the monitor the fiber optic cable connected was labeled #2. The issue was resolved by changing the fiber optic cable at the monitor to channel #1. No parts required replacement. No parts were returned to the manufacturer for evaluation.
 
Event Description
A medtronic representative reported that while in a procedure the touch screen monitor on the navigation system showed "searching for dvi connection". The monitor is not functioning. The site used the other monitors and proceeded with the case. There was no delay to the procedure as a result of this issue and no impact on the patient outcome.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameSTEALTHSTATION I7 INTEGRATED NAVIGATION SYSTEM
Type of DeviceNEUROLOGICAL STEREOTAXIC INSTRUMENT
Manufacturer (Section D)
MEDTRONIC NAVIGATION, INC. (LOUISVILLE)
826 coal creek circle
louisville CO 80027
Manufacturer (Section G)
MEDTRONIC NAVIGATION, INC. (LOUISVILLE)
826 coal creek circle
louisville CO 80027
Manufacturer Contact
peter verhey
attn:product quality experienc
826 coal creek circle
louisville, CO 80027-9710
7635267745
MDR Report Key7172031
MDR Text Key103073950
Report Number1723170-2018-00094
Device Sequence Number1
Product Code HAW
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K050438
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,other
Reporter Occupation Medical Equipment Company Technician/Representative
Type of Report Initial,Followup,Followup
Report Date 05/08/2019
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received01/08/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Model NumberI7
Device Catalogue Number9734060
Was Device Available for Evaluation? No Answer Provided
Is the Reporter a Health Professional? No
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received05/08/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured04/25/2016
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse

-
-