Model Number T177
Device Problems High impedance (1291); Over-Sensing (1438); Ambient Noise Problem (2877)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 10/30/2017
Event Type  Injury  
Manufacturer Narrative

The product has been received for analysis. This report will be updated upon completion of analysis.

 
Event Description

Boston scientific received information that this implantable cardioverter defibrillator (icd) exhibited noise on the right ventricular (rv) channel. The noise was oversensed, but did not result in asystole greater than 2 seconds. The patient was seen in clinic and the noise could not be reproduced. In addition, varying impedances on the rv were observed. The average range was 380-460 ohms until recently when the values increased to 390-520 ohms. Therapy was programmed off until the following day when the lead was surgically abandoned and replaced. This icd was also removed and replaced with a cardiac resynchronization therapy defibrillator (crt-d). During the revision procedure, the lead was not tested. No additional adverse patient effects were reported.

 
Manufacturer Narrative

Upon receipt at our post market quality assurance laboratory, a thorough evaluation of the device was performed. A visual inspection of the device header and case noted no anomalies. Pin gauge testing, designed to verify proper port dimensions, was completed. Each port measured as expected. The device was then exposed to simulated heart load conditions, and the defibrillation, pacing, and sensing functions were tested. Impedance testing was completed and all measurements were within normal limits. The device operated appropriately with no interruptions in therapy output at the returned programmed settings. A series of electrical tests was also performed, and again, normal device function was observed. Analysis did not identify any device characteristics that would have caused or contributed to the reported clinical observations.

 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameVITALITY 2
Type of DeviceIMPLANTABLE CARDIOVERTER DEFIBRILLATOR
Manufacturer (Section D)
GUIDANT CRM CLONMEL IRELAND
guidant ireland
clonmel, tipperary ireland
Manufacturer (Section G)
GUIDANT CRM CLONMEL IRELAND
guidant ireland
clonmel, tipperary ireland
Manufacturer Contact
tim degroot
4100 hamline ave. n
st. paul, MN 
6515826168
MDR Report Key7196965
MDR Text Key97471170
Report Number2124215-2018-00124
Device Sequence Number1
Product Code KRG
Combination Product (Y/N)N
Reporter Country CodeUS
PMA/PMN NumberP960040/S039
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type COMPANY REPRESENTATIVE
Reporter Occupation
Type of Report Initial,Followup
Report Date 01/08/2018
1 Device Was Involved in the Event
1 Patient Was Involved in the Event
Date FDA Received01/16/2018
Is This An Adverse Event Report? Yes
Is This A Product Problem Report? Yes
Device Operator LAY USER/PATIENT
Device EXPIRATION Date02/12/2008
Device MODEL NumberT177
OTHER Device ID NumberVITALITY 2 VR EL
Was Device Available For Evaluation? Device Returned To Manufacturer
Date Returned to Manufacturer12/20/2017
Is The Reporter A Health Professional? Yes
Was the Report Sent to FDA? Yes
Event Location No Information
Date Manufacturer Received01/08/2018
Was Device Evaluated By Manufacturer? Yes
Date Device Manufactured02/16/2007
Is The Device Single Use? Yes
Is this a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient TREATMENT DATA