Model Number H7493808012270
Device Problems Material Rupture (1546); Material Deformation (2976)
Patient Problem Intimal Dissection (1333)
Event Date 01/11/2018
Event Type  Injury  
Manufacturer Narrative
(b)(4). The device has not been received for analysis. Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed. (b)(4).
 
Event Description
It was reported that balloon rupture, shaft inflation and vessel dissection occurred. The target lesion was located in the left anterior descending artery. A 2. 75mm x 12mm quantum¿ maverick¿ balloon catheter was advanced to dilate the lesion. However, upon inflation the balloon ruptured in the stent and vessel dissection was noted. The device was removed from the patient. It was then noted that the balloon shaft inflated. Another bsc balloon was used to treat the dissection and the procedure was completed. No further patient complications were reported and the patient's status was stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameQUANTUM¿ MAVERICK¿
Type of DeviceCATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC - MAPLE GROVE
one scimed place
maple grove MN 55311
Manufacturer Contact
sonali arangil
one scimed place
maple grove, MN 55311
7634941700
MDR Report Key7211391
MDR Text Key97944541
Report Number2134265-2018-00433
Device Sequence Number1
Product Code LOX
Combination Product (y/n)N
PMA/PMN Number
P860019
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Type of Report Initial
Report Date 01/11/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/22/2018
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date11/12/2020
Device Model NumberH7493808012270
Device Catalogue Number38080-1227
Device Lot Number0021382763
Was Device Available for Evaluation? No
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received01/11/2018
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured11/13/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 01/22/2018 Patient Sequence Number: 1
-
-