COOK INC ADVANCE 14 LP LOW PROFILE BALLOON CATHETER; DQY CATHETER, PERCUTANEOUS Back to Search Results
Catalog Number PTAX4-14-110-2.5-12
Device Problems Leak/Splash (1354); Material Rupture (1546); Device Operational Issue (2914)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
(b)(4).This report includes information known at this time.A follow-up report will be submitted should additional relevant information become available.
 
Event Description
It was reported that during an angioplasty, the advance 14 lp low profile balloon catheter deflated at around 11 atmosphere (atm) and could not hold pressure.The catheter ruptured prior to reaching 12 atm; the balloon itself did not rupture.No optimal immediate result could be achieved as the stenosis was only able to be dilated at 10 atm.During inspection following the procedure, the balloon was observed to not be damaged; however, a leak at the level of the catheter was noted.It was noted that this was the first time this event had occurred in the past few weeks (second incident medwatch 1820334-2018-00204, third incident medwatch 1820334-2018-00205).A section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.
 
Manufacturer Narrative
(b)(4).Investigation - evaluation: a review of the complaint history, drawings, device history record, documentation, instructions for use (ifu), manufacturing instructions, specifications, and quality control was conducted during the investigation.The complaint device was not returned; therefore no physical examination could be performed.However, a document-based investigation was performed.There is no evidence to suggest the finished product was not made to specifications.Numerous design verification and validation activities have been performed to ensure that this device meets design requirements.The manufacturing processes in place at the time of manufacture were reviewed and it was found that the balloon material, distal, and proximal joints are quality control checked 100% for foreign matter and surface defects.Inflation/deflation verification testing, balloon minimum burst strength verification testing, and balloon fatigue verification testing was performed on the balloons.Review of the device history record of the finished product shows no nonconforming events that could contribute to this failure mode.A complaint history search revealed that there were two other reported complaints for this lot number (created for the second and third occurrence of this event referred to in the initial report).Per the ifu, "upon removal from package, inspect the catheter to ensure no damage has occurred during shipping.The balloon is manufactured from an extra-thinwall, high-strength, minimally-compliant material.Particular care should be taken in handling the balloon to prevent damage.It will inflate to the indicated size parameters when utilizing proper pressure recommendation.Do not exceed rated burst pressure.Rupture of balloon may occur.Over-inflation may cause rupture of the balloon, with resultant damage to the vessel wall.Use of a pressure gauge is recommended to monitor inflation pressures.Choose a balloon appropriate to lesion length and vessel diameter.If balloon pressure is lost and/or balloon rupture occurs, deflate balloon and remove balloon and sheath as a unit.Upon catheter withdrawal, a gentle counterclockwise rotation of the catheter will assist balloon rewrap, minimizing resistance through the sheath.If resistance is met during withdrawal, apply negative pressure with a larger syringe before proceeding.If resistance continues, remove balloon and sheath as a unit." based on the information provided, no product returned, and the results of our investigation, a definitive root cause could not be determined.Per the quality engineering risk assessment, no further action is required.The appropriate personnel have been notified, and monitoring will continue to be performed for similar complaints.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVANCE 14 LP LOW PROFILE BALLOON CATHETER
Type of Device
DQY CATHETER, PERCUTANEOUS
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
Manufacturer Contact
larry pool
750 daniels way
bloomington, IN 47404
8123392235
MDR Report Key7222849
MDR Text Key98519918
Report Number1820334-2018-00203
Device Sequence Number1
Product Code DQY
UDI-Device Identifier10827002187990
UDI-Public(01)10827002187990(17)201016(10)8295456
Combination Product (y/n)N
PMA/PMN Number
K090822
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,u
Reporter Occupation Pharmacist
Type of Report Initial,Followup
Report Date 03/13/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/26/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberPTAX4-14-110-2.5-12
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/12/2018
Date Device Manufactured10/16/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-