Model Number SYM2015OS
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Tissue Damage (2104)
Event Date 02/02/2018
Event Type  Injury  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
According to the reporter, during an open ventral hernia repair procedure, while being applied for intraperitoneal onlay mesh - ipom, the device was used, however patient incurred tissue damage, wherein small bowel was meshed.In order to resolve the issue, specimen was collected for microscopic examination.Surgical intervention such as the resection of small bowel meshed and temporary ileostomy were done in order to prevent a permanent impairment of a function.As a result, there was prolonged surgery due to removal of the mesh.Patient was alive.
 
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYMBOTEX
Type of Device
MESH, SURGICAL, POLYMERIC
Manufacturer (Section D)
SOFRADIM PRODUCTION SAS
116 avenue du formans
trevoux 01600
FR  01600
Manufacturer (Section G)
SOFRADIM PRODUCTION SAS
116 avenue du formans
trevoux 01600
FR   01600
Manufacturer Contact
lisa hernandez
60 middletown avenue
north haven, CT 06473
2034925563
MDR Report Key7310816
MDR Text Key101419031
Report Number9615742-2018-00411
Device Sequence Number1
Product Code FTL
UDI-Device Identifier10884521190467
UDI-Public10884521190467
Combination Product (y/n)N
Reporter Country CodeSZ
PMA/PMN Number
K131969
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,u
Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date 08/29/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/02/2018
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date11/30/2021
Device Model NumberSYM2015OS
Device Catalogue NumberSYM2015OS
Device Lot NumberPQL0184X
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/21/2018
Is the Reporter a Health Professional? Yes
Date Manufacturer Received08/13/2018
Date Device Manufactured12/24/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other; Required Intervention;
Patient Age57 YR
-
-