• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: OLYMPUS MEDICAL SYSTEMS CORP. HIGH FLOW INSUFFLATION UNIT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

OLYMPUS MEDICAL SYSTEMS CORP. HIGH FLOW INSUFFLATION UNIT Back to Search Results
Model Number UHI-4
Device Problem Device Operates Differently Than Expected (2913)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 04/16/2018
Event Type  malfunction  
Manufacturer Narrative
The referenced uhi-4 was not returned to olympus medical systems corp.(omsc) for evaluation, therefore omsc cannot evaluate the uhi-4.The technician of (b)(4) confirmed the referenced uhi-4 and found that there was no abnormality and irregularity.The exact cause of this phenomenon cannot be conclusively determined at the current moment.There were no further details provided.If significant additional information is received, this report will be supplemented.
 
Event Description
Olympus was informed that before the laparoscopic cholecystectomy, the facility found that the pressure of the uhi-4 was abnormal.The patient was already under anesthesia.The facility changed the uhi-4 to the other similar device and the procedure was completed.There was no report of the patient¿s injury regarding this event.
 
Manufacturer Narrative
This is a supplemental report for mfr report #8010047-2018-00829 to provide the device evaluation results.Omsc checked the device history record of the referenced uhi-4, there was no irregularity found.There were no further details provided.If significant additional information is received, this report will be supplemented.
 
Manufacturer Narrative
This is a supplemental report for mfr report #8010047-2018-00829 to provide the device evaluation results.The referenced uhi-4 was returned to olympus medical systems corp.(omsc) for evaluation.Omsc evaluated the uhi-4 and found that the uhi-4 could operate correctly for the setting value of the cavity pressure, however the volume indicator on the front panel of the uhi-4 displayed abnormal value.Furthermore, omsc checked the inside of the uhi-4 and found that the battery on the pc board was removed.Also, there was the damage due to impact on the exterior of the uhi-4.Omsc is continuously evaluating the uhi-4.There were no further details provided.If significant additional information is received, this report will be supplemented.
 
Manufacturer Narrative
This is a supplemental report to provide additional information.It was confirmed there was rusty at the rear panel of the subject device.Olympus medical systems corp.(omsc) investigated the internal circuit board of the subject device and found a flow sensor had malfunction.Based on the investigation result so far, omsc determined that the failure phenomenon, which the pressure of the subject device was abnormal, was attributed to the malfunctioned flow sensor in the subject device.The exact cause of malfunction of the flow sensor could not be conclusively determined, however there is the possibility that malfunction of the flow sensor might be attributed to operating environment or external impacts due to inappropriate handling of the device by the user.The uhi-4 instruction manual states the appropriate handling and operating environment of the device.
 
Manufacturer Narrative
This supplemental report is submitting to correct "device product code".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HIGH FLOW INSUFFLATION UNIT
Type of Device
HIGH FLOW INSUFFLATION UNIT
Manufacturer (Section D)
OLYMPUS MEDICAL SYSTEMS CORP.
2951 ishikawa-cho
hachioji-shi, tokyo-to 192-8 507
JA  192-8507
MDR Report Key7532488
MDR Text Key109030339
Report Number8010047-2018-00829
Device Sequence Number1
Product Code HIF
Combination Product (y/n)N
PMA/PMN Number
K110294
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Type of Report Initial,Followup,Followup,Followup,Followup
Report Date 08/23/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/22/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberUHI-4
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Date Manufacturer Received08/06/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-