Model Number AU00T0
Device Problem Material Fragmentation (1261)
Patient Problem Device Embedded In Tissue or Plaque (3165)
Event Date 05/09/2018
Event Type  malfunction  
Manufacturer Narrative
Evaluation summary: investigation including root cause analysis is in progress. A supplemental mdr will be filed as necessary in accordance with 21 cfr 803. 56 when additional reportable information becomes available. The manufacturer internal reference number is: (b)(4).
 
Event Description
A customer reported finding a tiny piece of the intraocular lens (iol) haptic remained in the preloaded delivery system following implant. The lens was left in the patient's eye and is not currently experiencing any issues. Additional information was requested.
 
Manufacturer Narrative
The product was not returned. Product history records were reviewed and the documentation indicated the product met release criteria. Viscoelastic was not provided. It is unknown if a qualified product was used. The product investigation could not identify a root cause. It is unknown if a qualified viscoelastic was used. Material properties of non-qualified viscoelastics may contribute to underfill, overfill, misfolding of the haptics, or other inconsistent folding outcomes. The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameACRYSOF IQ SINGLEPIECE IOL WITH ULTRASERT DELIVERY SYSTEM
Type of DeviceLENS, GUIDE, INTRAOCULAR
Manufacturer (Section D)
ALCON RESEARCH, LTD. - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer (Section G)
ALCON RESEARCH, LTD. - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer Contact
bryan blake
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8176152230
MDR Report Key7587566
MDR Text Key111161453
Report Number1119421-2018-00739
Device Sequence Number1
Product Code KYB
Combination Product (y/n)N
Reporter Country CodeNO
PMA/PMN Number
P930014
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Reporter Occupation
Type of Report Initial,Followup
Report Date 08/13/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/11/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date10/31/2020
Device Model NumberAU00T0
Device Lot Number12578574
Other Device ID Number00380652394826
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received07/24/2018
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured11/07/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 06/11/2018 Patient Sequence Number: 1
-
-