Catalog Number 382533
Device Problem Appropriate Term/Code Not Available (3191)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 06/26/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(6).A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event Description
It was reported with the use of the bd insyte¿ autoguard¿ bc there was an issue with foreign matter.There was no report of injury or further medical intervention.
 
Manufacturer Narrative
Due to an it issue beginning on 7/3/2018, previously filed emdrs did not contain required fields.This supplemental emdr is filed to provide the following omitted fields: event attributed to: other; device single use?: no; device returned to manufacture: yes.Investigation summary: received one unused unit in an open package from lot number 7276764.All components were present.The unit was received along with a picture and a note from the customer.Dhr review: the lot number was built on afa line 11, from october 14, 2017 thru october 18, 2017.Per review of the dhr it was concluded that all required challenges samples and testing was performed per specification in accordance with the in-process sampling plans.Per review it was noted that there were no reject activity findings throughout the build of this lot that would impact upon the quality of the product.In process samples for foreign/non-foreign material, particulate loose or embedded were performed on various stages throughout the process, all the inspections passed per specifications.No significant discoveries were found.The white speck observed on the picture provided by the customer was confirmed to be non-foreign (plug shavings) and to have resulted from manufacturing during the assembly process.A formal corrective action will not be initiated at this time.Customer complaint trends are evaluated on a monthly basis.If the trend of a specific type of complaint warrants a formal corrective action, resources will be assigned at that time.
 
Event Description
It was reported with the use of the bd insyte¿ autoguard¿ bc there was an issue with foreign matter.There was no report of injury or further medical intervention.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD INSYTE¿ AUTOGUARD¿ BC
Type of Device
INTRAVASCULAR CATHETER
Manufacturer (Section D)
BECTON DICKINSON INFUSION THERAPY SYSTEMS INC.
9450 south state street
sandy UT 84070
MDR Report Key7702850
MDR Text Key114711150
Report Number1710034-2018-00406
Device Sequence Number1
Product Code FOZ
UDI-Device Identifier30382903825333
UDI-Public30382903825333
Combination Product (y/n)N
PMA/PMN Number
K110443
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,other,user facility
Type of Report Initial,Followup
Report Date 08/24/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/19/2018
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date09/30/2020
Device Catalogue Number382533
Device Lot Number7276764
Date Manufacturer Received06/27/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Other;
-
-