Model Number PED-500-35
Device Problems Mechanical Problem (1384); Migration or Expulsion of Device (1395)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 06/13/2018
Event Type  malfunction  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
Medtronic received a report that the pipeline flow diverter failed to deploy. The device was then removed from the patient and tested outside, but it would still not deploy. Additional information received reported that the physician was attempting to place the pipeline as conjoining with a previously placed pipeline. The device was then replaced with a new one which seemed to be placed as expected, but was then confirmed to show that the distal end was dislodged from the pipeline originally placed. It was determined that this dislodgement was due to the new pipeline being conjoined too closely to the original, causing the new device to be stretched too much in order to cover the target aneurysm. The patient was undergoing surgery for a cerebral aneurysm flow diversion with a slightly severe vessel tortuosity. The ancillary devices include the launcher guiding catheter and marksman microcatheter. There were no patient symptoms alleged and no medical intervention was required.
 
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NamePIPELINE FLEX
Type of DeviceINTRACRANIAL ANEURYSM FLOW DIVERTER
Manufacturer (Section D)
MICRO THERAPEUTICS, INC. D/B/A EV3 NEUROVASCULAR
9775 toledo way
irvine CA 92618
Manufacturer (Section G)
MICRO THERAPEUTICS, INC. D/B/A EV3 NEUROVASCULAR
9775 toledo way
irvine CA 92618
Manufacturer Contact
tricha miles
9775 toledo way
irvine, CA 92618
9492753836
MDR Report Key7704065
MDR Text Key114801666
Report Number2029214-2018-00633
Device Sequence Number1
Product Code OUT
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation
Type of Report Initial,Followup
Report Date 10/04/2018
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received07/19/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date01/29/2021
Device Model NumberPED-500-35
Device Catalogue NumberPED-500-35
Device Lot NumberA589182
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received08/08/2018
Was Device Evaluated by Manufacturer? No Answer Provided
Date Device Manufactured01/30/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-