Catalog Number PCF030120130
Device Problems Burst Container or Vessel (1074); Insufficient Information (3190)
Patient Problems No Consequences Or Impact To Patient (2199); Rupture (2208)
Event Date 06/20/2018
Event Type  malfunction  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
The physician was attempting to use a pacific xtreme balloon to treat a moderately calcified plaque lesion (60% stenosis) in the superficial femoral artery. The artery had no tortuosity. The device was prepped with no issues identified. Spider fx embolic protection was used. The device did not pass through a previously deployed stent and no excessive force was used. No resistance was encountered. During the first balloon inflation with a pressure pump at 7 atm a circumferential/radial burst occurred. The procedure was completed using another balloon the same make and size.
 
Manufacturer Narrative
Additional information: the damage in the equipment was observed during the preparation process and after opening the device. The top could not pass through the guide wire. If information is provided in the future, a supplemental report will be issued.
 
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NamePACIFIC XTREME
Type of DeviceCATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
MEDTRONIC MEXICO
avenida paseo del cucapah #105
parque industrial el lago
tijuana,bc 22570
MX 22570
Manufacturer (Section G)
MEDTRONIC MEXICO
avenida paseo del cucapah #105
parque industrial el lago
tijuana,bc 22570
MX 22570
Manufacturer Contact
toni o'doherty
parkmore business park west
galway 
091708734
MDR Report Key7705619
MDR Text Key114812630
Report Number9612164-2018-01803
Device Sequence Number1
Product Code LIT
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K103464
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation
Type of Report Initial,Followup,Followup
Report Date 10/03/2018
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received07/20/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date12/13/2020
Device Catalogue NumberPCF030120130
Device Lot Number214581210
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received08/08/2018
Was Device Evaluated by Manufacturer? No Answer Provided
Date Device Manufactured12/13/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-