Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Respiratory Failure (2484)
Event Type  malfunction  
Manufacturer Narrative
Literature citation: utility of cement augmentation via percutaneous fenestrated pedicle screws for stabilization of cancer related spinal instability by ilya laufer, md.Age at event: age distribution was 18 to 87 years, with an average age of 63.5 years.Sex: gender distribution was 23 females and 30 males.Date of event: unknown.Neither the device nor films of applicable imaging studies were returned to the manufacturer for evaluation.Therefore, we are unable to determine the definitive cause of the reported event.Although it is unknown whether the product caused or contributed to the reported event, we are filling this mdr for notification purpose.If information is provided in the future, a supplemental report will be issued.
 
Event Description
It was reported in the literature that fifty-three patients were included in the analysis.Patients with neoplastic spinal instability underwent percutaneous instrumented spinal stabilization with cement augmentation using fenestrated pedicle screws.Cement augmentation was performed in 216 fenestrated pedicle screws.A postoperative mortality secondary to pulmonary failure from widespread metastatic pulmonary infiltration has been reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CD HORIZON SPINAL SYSTEM
Type of Device
ORTHOSIS, SPINAL PEDICLE FIXATION, FOR DEGENERATIVE DISC DISEASE
Manufacturer (Section D)
MEDTRONIC SOFAMOR DANEK
1800 pyramid place
memphis TN 38132
Manufacturer (Section G)
MEDTRONIC SOFAMOR DANEK
1800 pyramid place
memphis TN 38132
Manufacturer Contact
stacie ziemba
1800 pyramid place
memphis, TN 38132
9013963133
MDR Report Key8296040
MDR Text Key134736407
Report Number1030489-2019-00104
Device Sequence Number1
Product Code NKB
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type literature
Reporter Occupation Physician
Type of Report Initial
Report Date 02/01/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/01/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received01/04/2019
Was Device Evaluated by Manufacturer? No
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
Patient Outcome(s) Other;