Catalog Number 209999
Device Problems Computer Software Problem (1112); Output Problem (3005)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 02/19/2019
Event Type  malfunction  
Manufacturer Narrative
As part of the normal complaint follow-up, an evaluation of the event has been initiated by mako surgical. A supplemental report will be submitted when additional information becomes available.
 
Event Description
During impaction, surgeon did not believe cup placement according to the robot was correct. Case type: tha. Surgical delay: yes, about 20 mins longer because he ended up manually reaming more to medialize then impact manually. What is the estimated discrepancy mentioned in the complaint in regard to the resultant cup placement? tha (degrees). As per the mps: where he believed was 40 inclination and 20 version but when the robot engaged during impaction it would shift posteriorly and would leave the put overhanging a great deal but i couldn¿t tell you an estimation of how much he felt it was off. Where he believed he placed it was 40 inclination and 20 version however after checking the cup it said something like 51 inclination and 8 version but i¿m not sure the exact numbers they were capture and should be in the file. He was happy with the overall cup placement done manually.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name3.0 RIO® ROBOTIC ARM - MICS
Type of DeviceSTEREOTAXIC DEVICE, ROBOTICS
Manufacturer (Section D)
MAKO SURGICAL CORP.
2555 davie road
fort lauderdale FL 33317
Manufacturer (Section G)
MAKO SURGICAL CORP.
2555 davie road
fort lauderdale FL 33317
Manufacturer Contact
bethany hinson
2555 davie road
fort lauderdale, FL 33317
9546280700
MDR Report Key8391884
MDR Text Key138141048
Report Number3005985723-2019-00202
Device Sequence Number1
Product Code OLO
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation
Type of Report Initial,Followup
Report Date 06/17/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/05/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Catalogue Number209999
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received05/31/2019
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse

Patient Treatment Data
Date Received: 03/05/2019 Patient Sequence Number: 1
-
-