Catalog Number SGC0301
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Fistula (1862)
Event Date 02/12/2019
Event Type  Injury  
Manufacturer Narrative
(b)(4). During processing of this complaint, attempts were made to obtain complete event, patient and device information. The device was not returned for evaluation. A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event. The reported patient effect of arterio-venous fistula as listed in the mitraclip system instructions for use is a known possible complication associated with mitraclip procedures. A conclusive cause for the reported patient effect and the relationship to the product, if any, cannot be determined. There is no indication of a product quality issue with respect to manufacture, design or labeling. The implanted clip referenced is filed under a separate medwatch report.
 
Event Description
This is filed to report the fistula. It was reported that this was a mitraclip procedure to treat degenerative mitral regurgitation (mr) with a grade of 4. The mitraclip delivery system (cds) was advanced to the mitral valve. The clip was deployed on the leaflets without issue. However, the clip detached from the anterior leaflet and remained attached to the posterior leaflet (single leaflet device attachment/slda). A second clip was implanted, stabilizing the slda clip. Mr was reduced to 2. When removing the steerable guide catheter (sgc), a fistula was observed in the right femoral vein. A stent was used to treat/seal the fistula. The patient did well. There was no additional information provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameMITRACLIP SYSTEM STEERABLE GUIDE CATHETER
Type of DeviceSTEERABLE GUIDE CATHETER
Manufacturer (Section D)
AV-TEMECULA-CT
abbott vascular
26531 ynez road
temecula CA 92591 4628
Manufacturer (Section G)
MENLO PARK, CA REG# 3005070406
abbott vascular
26531 ynez rd.
temecula CA 92591 4628
Manufacturer Contact
connie speck
abbott vascular
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key8405358
MDR Text Key138287313
Report Number2024168-2019-01855
Device Sequence Number1
Product Code DRA
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K161985
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation
Remedial Action Other
Type of Report Initial
Report Date 03/08/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/08/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator
Device Expiration Date11/26/2019
Device Catalogue NumberSGC0301
Device Lot Number81126U152
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received02/12/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured11/01/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 03/08/2019 Patient Sequence Number: 1
Treatment
CLIP DELIVERY SYSTEM X2
-
-