Device Problem Device Damaged by Another Device (2915)
Patient Problem No Code Available (3191)
Event Type  Injury  
Manufacturer Narrative
This report is for an unknown plate/unknown lot. Part and lot number are unknown; udi number is unknown. Complainant part is not expected to be returned for manufacturer review/investigation. (b)(4). Without a lot number the device history records review could not be completed. The investigation could not be completed; no conclusion could be drawn, as no product was received. The investigation could not be completed; no conclusion could be drawn, as no product was received. Device was used for treatment, not diagnosis. If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
It was reported that on an unknown date, the patient underwent a variable angle- locking compression plate olecranon plate removal due to discomfort. During the procedure, the screw to be removed proximally was cold welded in the plate. The surgeon has to bend the plate with his fingers in order to clear soft tissues and allow to rotate the last screw plate assembly in order to remove the construct from the patient. There was a sixty (60) minutes surgical delay. The procedure was successfully completed with no patient consequence. This complaint involves two (2) devices. This report is 2 of 2 for (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Type of DevicePLATE, FIXATION, BONE
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
Manufacturer Contact
kara ditty-bovard
1302 wrights lane east
west chester, PA 19380
6103142063
MDR Report Key8485447
MDR Text Key141010172
Report Number2939274-2019-57285
Device Sequence Number1
Product Code HRS
Combination Product (y/n)N
Reporter Country CodeCA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation
Type of Report Initial,Followup
Report Date 03/12/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/04/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received05/30/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device?
Type of Device Usage Unkown

Patient Treatment Data
Date Received: 04/04/2019 Patient Sequence Number: 1
-
-