Manufacturer Narrative
|
The reported event could not be confirmed, since the device was not returned for evaluation and no other evidences were provided.This complaint has been reported during a literature review performed by the post market surveillance group.No product identification is possible.More detailed information about the complaint event as well as the affected device must be available in order to determine the root cause of the complaint event.The reviewed ifu, however, states that ¿early or late infection, both deep or superficial¿ is one of the most frequent adverse effects involving the use of internal fracture fixation devices and adverse results may be clinically related rather than device related.Also, the surgeon must warn patients of surgical risks, and make them aware of possible adverse effects.The patient should be warned that the device cannot and does not replicate a normal healthy bone, that the device can break or become damaged as a result of strenuous activity or trauma.Based on the available information, no relation could be established between the device and the reported event.A review of the labeling did not indicate any abnormalities.If any further information is provided, the investigation report will be updated.Device evaluated by mfr: device disposition unknown.
|
|
Event Description
|
The manufacturer became aware of a post market clinical follow-up (pmcf) from (b)(6) medical campus ((b)(6)).The title of this report is ¿a post-market clinical follow-up (pmcf) of the treatment of fractures with the apex pins in conjunction with stryker external fixation systems¿ which was published in april 2019 and is associated with the stryker apex pin.Within that publication, post-operative complications/ adverse events were reported, which occurred between november 2012 to september 2018.It was not possible to ascertain specific device or patient information from the article; a review of the complaint handling database, however, revealed that the events have not been reported by the hospital or by the author of the publication.Therefore, 52 complaints were initiated retrospectively for different adverse events mentioned in the journal.This product inquiry addresses pin tract infection.3 out of 15 cases.The report states, ¿subject (b)(6) was a (b)(6) (race unknown) female, who sustained right open tibia fracture from a fall from height.A stryker hoffman 3 external fixator was applied along with 5 stryker apex pins for definitive treatment.No other orthopaedic injuries occurred; a history of diabetes and previous tobacco use was noted.The subject was discharged to a skilled nursing facility on pod 7, nonweightbearing status.Subject was 4 weeks out from external fixator placement when it was noted by the orthopaedic surgeon that there was ¿purulent drainage and erythema on both medial and lateral side¿ at her calcaneus pin.Antibiotics were prescribed for a period of 8 weeks due to noncompliance with pin care regimen and antibiotic treatment.At a 10 week post-op follow-up, the orthopaedic surgeon removed her external fixator in the clinic (70 days from surgery) and she continued her course of antibiotics for two additional weeks; at her 13.5 week visit the infection was determined to be cleared by the orthopaedist.¿.
|
|
Search Alerts/Recalls
|
|