Catalog Number UNK HIP ACETABULAR LINER |
Device Problems
Nonstandard Device (1420); Naturally Worn (2988)
|
Patient Problems
Foreign Body Reaction (1868); Pain (1994); Tissue Damage (2104); No Code Available (3191)
|
Event Type
Injury
|
Manufacturer Narrative
|
(b)(4).No 510(k) number provided because this implant is sold internationally with different indications for use; it is currently sold in the us under a different part number.The correction/removal reporting number listed applies to the corresponding product code sold domestically.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Event Description
|
An article ¿cobalt from metal-on-metal hip replacements may be the clinically relevant active agent responsible for periprosthetic tissue reactions¿ by alister j.Hart et al reports on difference in the relative amounts of implant-derived metals in the tissues and in the chemical speciation of the debris.It was performed through an ex vivo analysis of periprosthetic capsular tissue from 12 patients in two groups, ultima and non-ultima (5 females and 1 male, median age=27) that included two resurfacing asr and one modular asr during revision of mom hips (insitu for atleast 18 months) that failed without evidence of infection or a mechanical problem such as dislocation or impingement during the period february 2008 to september 2010.Reason for revision was unexplainable pain for all cases.No clarification was found on which events were specifically present on specific patients.2 cases of pseudotumors and one case of partial avulsion of the gluteus medius tendon were reported in non-ultima group in which asr was used.Synchrotron x-ray analysis of periprosthetic tissue revealed that co (in either the metallic or 2+ oxidation states) may be the clinically relevant active species derived from mom hips that is responsible for unexplained failures due to tissue inflammation.The relative amount of co, when compared with cr, and visible corrosion was found on the ultima femoral stems.
|
|
Manufacturer Narrative
|
(b)(4).No device was received.Root cause undetermined.Depuy synthes considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation may be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Search Alerts/Recalls
|