Model Number PCO3020
Device Problems Loss of or Failure to Bond (1068); Material Erosion (1214); Migration or Expulsion of Device (1395); Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Abscess (1690); Adhesion(s) (1695); Erosion (1750); Purulent Discharge (1812); Erythema (1840); Fistula (1862); Unspecified Infection (1930); Necrosis (1971); Pain (1994); Hernia (2240); Injury (2348); Impaired Healing (2378)
Event Type  Injury  
Manufacturer Narrative
This information was received as a part of an extensive mesh litigation submission to medtronic. The fda was notified of this large complaint receipt. Due to the volume of complaint information received by medtronic, this resulted in a report beyond the 30 day target. If information is provided in the future, a supplemental report will be issued.
 
Event Description
The patient¿s attorney alleged a deficiency against the device. The product was used for therapeutic treatment of right lower quadrant parastomal and incisional midline hernias. It was reported that after implant, the patient experienced recurrence, infected mesh, abdominal wound, mesh migration, dense adhesions, fistula, and abscess. Post-operative patient treatment included revision surgery, repair of hernia with mesh, excisional debridement of skin, subcutaneous tissue and infected mesh, removal of mesh foreign body, and incision and drainage of abdominal wall.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameMESH SOFRADIM - PARIETEX¿ COMPOSITE MESH
Type of DeviceMESH, SURGICAL, POLYMERIC
Manufacturer (Section D)
SOFRADIM PRODUCTION SAS
116 avenue du formans
trevoux 01600
FR 01600
Manufacturer (Section G)
SOFRADIM PRODUCTION SAS
116 avenue du formans
trevoux 01600
FR 01600
Manufacturer Contact
lisa hernandez
60 middletown ave.
north haven, CT 06473
2034925563
MDR Report Key8945166
MDR Text Key155977271
Report Number9615742-2019-02911
Device Sequence Number1
Product Code FTL
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K040998
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date 10/04/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/29/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date10/30/2016
Device Model NumberPCO3020
Device Catalogue NumberPCO3020
Device Lot NumberPLK00326
Was Device Available for Evaluation? No
Is the Reporter a Health Professional?
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received05/15/2019
Was Device Evaluated by Manufacturer? No Answer Provided
Date Device Manufactured11/29/2011
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 08/29/2019 Patient Sequence Number: 1
-
-