The account alleges that on (b)(6) 2019 a uterine artery embolization [uae] procedure was successfully performed.The patient experienced a uterine myoma expulsion, developed an intrauterine infection and necrosis post uae.A resection of the uterus was performed on an unknown date.On (b)(6) 2019, the patient was recovering from uterine myoma expulsion and intrauterine infection.
|
Additional information received from the account: on (b)(6) 2019, at around 23:00, the patient, who was experiencing pyrexia and abdominal pain for 2 months, visited the reporter's hospital as taking analgesics did not lead to any improvement.When she visited, she was seen by a gynecologist, and the gynecologist identified a dark red discharge.A white tissue 8 cm in size at the opening of the uterus was noted.Ultrasonography identified a mass 11 cm in size.On (b)(6) 2019, the day after admission, contrast enhanced computed tomography demonstrated myoma necrosis, development of gas and partial prolapse into the vagina, leading to the above mentioned diagnoses.Treating with antibiotics was considered difficult, and total hysterectomy was thus performed the same day.Inflammation subsequently improved.On (b)(6) 2019, the patient was discharged from the hospital.
|