Catalog Number H938724E
Device Problem Unsealed Device Packaging (1444)
Patient Problem No Patient Involvement (2645)
Event Type  malfunction  
Manufacturer Narrative
Event date: the event occurred on an unspecified date of (b)(6) 2019.Initial reporter address: (b)(6).Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported that a em2400 valve set had defective primary packaging (peel seam was opened).This issue was identified prior to use.There was no patient involvement.No additional information is available.
 
Manufacturer Narrative
Additional information was added : the device was manufactured between june 21, 2018 - june 22, 2018.The actual sample was received for evaluation.A visual inspection was performed which observed that the primary packaging was found opened on the right side only.Sufficient sealing appeared to have been observed on the opened seam section of the primary packaging.Top and bottom seals were not opened and no defect was observed of the valve set.The reported problem was verified.The cause of the reported condition could not be determined.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EUROPEAN VALVE SET, EM2400
Type of Device
SET, I.V. FLUID TRANSFER
Manufacturer (Section D)
BAXTER HEALTHCARE ¿ ROUND LAKE
round lake IL
Manufacturer (Section G)
BAXTER HEALTHCARE ¿ ROUND LAKE
25212 w. illinois route 120
round lake IL 60073
Manufacturer Contact
25212 w. illinois route 120
round lake, IL 60073
2242702068
MDR Report Key9106217
MDR Text Key159712786
Report Number1416980-2019-05202
Device Sequence Number1
Product Code LHI
Combination Product (y/n)N
Reporter Country CodeGM
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Pharmacist
Type of Report Initial,Followup
Report Date 11/13/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/23/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue NumberH938724E
Device Lot Number60133948
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/19/2019
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/07/2019
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
-
-