MAUDE Adverse Event Report: RESPIRONICS CALIFORNIA, INC V60 VENTILATOR; VENTILATOR, CONTINUOUS, MINIMAL VENTILATORY SUPPORT,FACILITY USE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

RESPIRONICS CALIFORNIA, INC V60 VENTILATOR; VENTILATOR, CONTINUOUS, MINIMAL VENTILATORY SUPPORT,FACILITY USE Back to Search Results
Model Number V60
Device Problem Incorrect, Inadequate or Imprecise Result or Readings (1535)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Type  malfunction  
Manufacturer Narrative
Date of event: (b)(6) 2019.Date of report: 10/23/2019.The manufacturer's remote service technician performed troubleshooting with the customer.The technician recommended that the customer replace the flow sensor assembly.
 
Event Description
It was reported that the unit was not delivering or reading tidal volumes correctly.When the unit was set to 10 liters per minute (lpm), it was reading 37 lpm.The device was in use at the time of the event; however, there was no patient harm.
 
Manufacturer Narrative
Mfr received date: (b)(6) 2019.The customer reported replacing the flow sensor assembly and the unit is passing flow testing.The issue was resolved.The device was being used for treatment when the reported event occurred, and there is a relationship between the device and the reported problem.No parts were returned to failure investigation; therefore, the root cause of the reported issue could not be determined.Submission of a report does not constitute an admission that medical personnel, user facility, importer, distributor, manufacturer, or product caused or contributed to the event.
 
Manufacturer Narrative
G4: 08feb2020, b4: 10feb2020.The gas delivery system (gds) was returned for failure analysis.A visual inspection revealed that the unit was received without the data acquisition board and oxygen valve.Also, one of the support standoffs for the data acquisition board was missing.During testing, it was determined that the unit failed due to the air flow sensor's u1 component drifting out of specification.Submission of a report does not constitute an admission that medical personnel, user facility, importer, distributor, manufacturer, or product caused or contributed to the event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
V60 VENTILATOR
Type of Device
VENTILATOR, CONTINUOUS, MINIMAL VENTILATORY SUPPORT,FACILITY USE
Manufacturer (Section D)
RESPIRONICS CALIFORNIA, INC
2271 cosmos court
carlsbad CA 92011
MDR Report Key9226047
MDR Text Key187576911
Report Number2031642-2019-10200
Device Sequence Number1
Product Code MNT
Combination Product (y/n)N
PMA/PMN Number
K082660
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,user f
Type of Report Initial,Followup,Followup
Report Date 10/10/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/23/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Model NumberV60
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/15/2020
Was the Report Sent to FDA? No
Date Manufacturer Received10/10/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
UNKNOWN PATIENT CIRCUIT, MASK AND HUMIDIFIER.
-
-