Model Number 23295
Device Problem Material Rupture (1546)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 10/28/2019
Event Type  malfunction  
Manufacturer Narrative
Initial reporter city: (b)(6).
 
Event Description
It was reported that balloon rupture occurred.The 90% stenosed target lesion was located in a moderately tortuous and moderately calcified vein.A 5.5-4/4t/90 symmetry balloon catheter was advanced for dilatation.However, during first inflation at 15 atmospheres, the balloon ruptured.The procedure was completed with a 6mm non-bsc device.No patient complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYMMETRY
Type of Device
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
ballybrit business park
galway
EI  
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key9313289
MDR Text Key172000706
Report Number2134265-2019-13749
Device Sequence Number1
Product Code LIT
UDI-Device Identifier08714729181934
UDI-Public08714729181934
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K143193
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Reporter Occupation Physician
Type of Report Initial
Report Date 11/12/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/12/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/07/2022
Device Model Number23295
Device Catalogue Number23295
Device Lot Number0023457333
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received10/28/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured03/08/2019
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial