MAKO SURGICAL CORP. 2.7 DEGREE STRAIGHT SAGITAL SAW; ORTHOPEDIC STEREOTAXIC INSTRUMENT Back to Search Results
Model Number 212186
Device Problems Device Slipped (1584); Activation, Positioning or Separation Problem (2906); Separation Problem (4043); Premature Separation (4045)
Patient Problems No Known Impact Or Consequence To Patient (2692); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/28/2019
Event Type  malfunction  
Manufacturer Narrative
As part of the normal complaint follow-up, an evaluation of the event has been initiated by mako surgical.A supplemental report will be submitted when additional information becomes available.
 
Event Description
The saw is coming loose from the saw attachments while cutting bone.Dr.Is requesting that all of his attachments be replaced because this has been happening frequently with all the attachments.Surgical delay = minutes.Case type: tka.Update: "this happened today with a straight and an offset attachment in the same case.We have had issues with the saw coming loose for the past week and today dr.(b)(6) decided he wanted all of the attachments replaced." "the blade did not fall out but it became loose while making cuts which made our cuts in accurate." surgical delay 3-5 min, left side.Update: "which cuts were inaccurate?-straight cuts were inaccurate how were the cuts inaccurate? (proud, deep, etc)the cuts were proud.What is the estimated discrepancy mentioned in the complaint? (tka angle(s) & mm)- about a mm off was the planar probe utilized to measure cut accuracy? no it was not- the trial did not fit- on the femur a/p.Are post-op x-rays available? (yes/no)- no.".
 
Manufacturer Narrative
Reported event: it was reported that the saw is coming loose from the saw attachments while cutting bone.Dr.Is requesting that all of his attachments be replaced because this has been happening frequently with all the attachments.Surgical delay = minutes.Product evaluation and results: product was not inspected as the product was not returned for evaluation.Product history review: device history records indicate (b)(4) were manufactured under lot 35060718 and (b)(4) were accepted into final stock on 08/28/2018.A review of qt-18-08-0103 revealed 02 rejected devices were re-inspected and accepted into final stock on 01/08/2019.Complaint history review: a review of complaints in catsweb and trackwise related to p/n 212186, lot number 35060718 shows 3 additional complaints related to the failure in this investigation.The complaints are (b)(4).Conclusions: the failure could not be determined as the product was not available for inspection.No additional investigation or specific actions are required.If additional information is received then the complaint will be reopened.Corrective action/preventive action: a review of stryker¿s nc/capa database indicated there have been no nc and capa associated with the product and failure mode reported in this event.H3 other text : device not returned.
 
Event Description
The saw is coming loose from the saw attachments while cutting bone.Dr.Is requesting that all of his attachments be replaced because this has been happening frequently with all the attachments.Surgical delay = minutes.Case type: tka.Update: "this happened today with a straight and an offset attachment in the same case.We have had issues with the saw coming loose for the past week and today dr.(b)(6) decided he wanted all of the attachments replaced." "the blade did not fall out but it became loose while making cuts which made our cuts in accurate." surgical delay 3-5 min, left side.Update: " 1.Which cuts were inaccurate? straight cuts were inaccurate 2.How were the cuts inaccurate? (proud, deep, etc)the cuts were proud 3.What is the estimated discrepancy mentioned in the complaint? (tka angle(s) & mm) about a mm off 4.Was the planar probe utilized to measure cut accuracy? no it was not- the trial did not fit- on the femur a/p 5.Are post-op x-rays available? (yes/no) no".
 
Event Description
The saw is coming loose from the saw attachments while cutting bone.Dr.Is requesting that all of his attachments be replaced because this has been happening frequently with all the attachments.Surgical delay = minutes.Case type: tka.Update: "this happened today with a straight and an offset attachement in the same case.We have had issues with the saw coming loose for the past week and today dr.(b)(6) decided he wanted all of the attachments replaced." "the blade did not fall out but it became loose while making cuts which made our cuts in accurate." surgical delay 3-5 min, left side.Update: " 1.Which cuts were inaccurate?- straight cuts were inaccurate 2.How were the cuts inaccurate? (proud, deep, etc)the cuts were proud 3.What is the estimated discrepancy mentioned in the complaint? (tka ¿ angle(s) & mm)- about a mm off 4.Was the planar probe utilized to measure cut accuracy? no it was not- the trial did not fit- on the femur a/p 5.Are post-op x-rays available? (yes/no)- no.".
 
Manufacturer Narrative
Reported event: it was reported that the saw is coming loose from the saw attachments while cutting bone.Dr.Is requesting that all of his attachments be replaced because this has been happening frequently with all the attachments.Surgical delay = minutes.Product evaluation and results: functional inspection confirmed the event.The ratcheting mechanism is broken and thus does not allow the saw attachment to clamp down fully on the blade to keep it in place.Product history review: device history records indicate 50 devices were manufactured under lot 35060718 and devices were accepted into final stock.A review revealed rejected devices were re-inspected and accepted into final stock on.Complaint history review: a review of complaints in catsweb and trackwise related to p/n 212186, lot number 35060718 shows 3 additional complaints related to the failure in this investigation.Conclusions: the failure was confirmed via functional inspection.No additional investigation or specific actions are required.If additional information is received then the complaint will be reopened.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
2.7 DEGREE STRAIGHT SAGITAL SAW
Type of Device
ORTHOPEDIC STEREOTAXIC INSTRUMENT
Manufacturer (Section D)
MAKO SURGICAL CORP.
2555 davie road
fort lauderdale FL 33317
MDR Report Key9328750
MDR Text Key181971163
Report Number3005985723-2019-00812
Device Sequence Number1
Product Code OLO
UDI-Device Identifier00848486032111
UDI-Public00848486032111
Combination Product (y/n)N
PMA/PMN Number
K143752
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Type of Report Initial,Followup,Followup
Report Date 03/15/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/15/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number212186
Device Catalogue Number212186
Device Lot Number35060718/3503645
Was Device Available for Evaluation? Yes
Date Manufacturer Received02/28/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Other;
-
-