MAUDE Adverse Event Report: COOK INC ADVANCE 14 LP LOW PROFILE BALLOON CATHETER LIT CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK INC ADVANCE 14 LP LOW PROFILE BALLOON CATHETER LIT CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL Back to Search Results
Model Number G50338
Device Problem Material Rupture (1546)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 08/07/2019
Event Type  malfunction  
Manufacturer Narrative
Pma/510(k) number
=
k170193. This report includes information known at this time. A follow-up report will be submitted should additional relevant information become available.
 
Event Description
As reported, during an endovascular therapy procedure, an advance 14 lp low profile balloon catheter ruptured. Access was gained in the femoral artery and a contralateral approach was used to treat a calcified lesion in the superficial femoral artery. The complaint device was advanced to the lesion and the user began to inflate the balloon, which ruptured at 12 atmospheres. It is unknown if the balloon ruptured circumferentially or longitudinally. The device was inflated outside of a stent. Another manufacturer's device was used to complete the procedure. There have been no adverse effects to the patient reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameADVANCE 14 LP LOW PROFILE BALLOON CATHETER
Type of DeviceLIT CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
Manufacturer (Section G)
COOK INC
750 daniels way
bloomington IN 47404
Manufacturer Contact
jennifer canada
750 daniels way
bloomington, IN 47404
8123392235
MDR Report Key9349460
MDR Text Key187459093
Report Number1820334-2019-02929
Device Sequence Number1
Product Code LIT
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,o
Reporter Occupation
Type of Report Initial,Followup,Followup
Report Date 03/12/2020
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received11/20/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date12/19/2021
Device Model NumberG50338
Device Catalogue NumberPTAX4-14-170-4-12
Device Lot Number9393784
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received03/03/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured12/19/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-