Catalog Number 1074300-23
Device Problems Difficult to Remove ; Material Separation; Improper or Incorrect Procedure or Method; Difficult to Advance; Material Deformation
Event Date 11/28/2019
Event Type  Malfunction  
Manufacturer Narrative

Exemption number e2019001. (b)(4). The device is expected to be returned for investigation. It has not yet been received. A follow-up report will be submitted with all additional relevant information.

 
Event Description

It was reported that the procedure was performed to treat a non-tortuous, moderately calcified, 80% stenosed mid left anterior descending coronary artery. A 3x23mm xience xpedition stent delivery system (sds) was being advanced when resistance with a non-abbott guiding catheter was noted. The sds was being removed when resistance with the same guiding catheter was noted, and some force was applied. The shaft of the sds separated and was removed along with the guiding catheter. The unimplanted stent was noted to have flared stent struts. Another 3x23mm xience xpedition stent was used to successfully complete the procedure. There were no adverse patient effects and no clinically significant delay in the procedure. No additional information was provided.

 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameXIENCE XPEDITION
Type of DeviceDRUG ELUTING CORONARY STENT DELIVERY SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005718570 (P099)
cashel road
clonmel tipperary
EI 
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula , CA 92591-4628
9519143996
MDR Report Key9488829
Report Number2024168-2019-14681
Device Sequence Number1
Product CodeNIQ
Report Source Manufacturer
Source Type COMPANY REPRESENTATIVE,FOREIG
Reporter Occupation
Type of Report Initial
Report Date 12/18/2019
1 Device Was Involved in the Event
0 PatientS WERE Involved in the Event:
Date FDA Received12/18/2019
Is This An Adverse Event Report? No
Is This A Product Problem Report? Yes
Device Operator HEALTH PROFESSIONAL
Device Catalogue Number1074300-23
Device LOT Number9061341
Was Device Available For Evaluation? Yes
Is The Reporter A Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received11/29/2019
Was Device Evaluated By Manufacturer? Device Not Returned To Manufacturer
Date Device Manufactured06/18/2019
Is The Device Single Use? Yes
Is this a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-