MEDIVANCE, INC. ¿ 1725056 ARCTICSUN 5000 ARCTIC SUN DEVICE Back to Search Results
Model Number 50000000E
Device Problems Device Displays Incorrect Message (2591); Device Sensing Problem (2917); Therapeutic or Diagnostic Output Failure (3023)
Patient Problems No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
The investigation is still in progress. Once the investigation is complete, a supplemental report will be filed. The device was not returned.
 
Event Description
It was reported that the arctic sun device was getting an alert during therapy. The baby's temperature was at 33. 1c with a target of 33. 5c. The water temperature was 31c, and the flow rate with a neonatal pad was 0. 5(l/min). The event log showed an alert 113 (reduced water temperature control), and the water level was showing three bars. The nurse disconnected and reconnected the pad using the proper technique, but the flow rate remained at 0. 5l/min. The device was swapped out and sent to biomed. The flow rate on the second device fluctuated from 0. 2-1. 5l/min, so the nurse was advised to swap the pad. After about an hour, the patient's temperature had increased to 33. 3c. Per follow up with nurse via phone on 13dec2019, the patient continued therapy on the second device with the second pad, with no further issues.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameARCTICSUN 5000
Type of DeviceARCTIC SUN DEVICE
Manufacturer (Section D)
MEDIVANCE, INC. ¿ 1725056
321 s taylor ave
louisville CO 80027
Manufacturer (Section G)
MEDIVANCE, INC. ¿ 1725056
321 s taylor ave
louisville CO 80027
Manufacturer Contact
yonic anderson
8195 industrial blvd
covington, GA 30014
7707846100
MDR Report Key9544745
MDR Text Key178644622
Report Number1018233-2020-00069
Device Sequence Number1
Product Code DWJ
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K161602
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,other,use
Reporter Occupation
Type of Report Initial,Followup
Report Date 02/13/2020
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received01/03/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Model Number50000000E
Device Catalogue Number50000000E
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received02/06/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured02/26/2019
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse

-
-