• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDTRONIC CRYOCATH LP FLEXCATH ADVANCE STEERABLE SHEATH CATHETER, STEERABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC CRYOCATH LP FLEXCATH ADVANCE STEERABLE SHEATH CATHETER, STEERABLE Back to Search Results
Model Number 4FC12
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Hematoma (1884); Vascular System (Circulation), Impaired (2572); Pseudoaneurysm (2605)
Event Date 01/01/2019
Event Type  Injury  
Manufacturer Narrative
Concomitant medical products: arctic front advance cardiac cryoablation catheter medtronic was made aware of this event through a search of literature publications. It was not possible to ascertain specific device information from the literature publication or to match the event with previously reported events. This information is based entirely on journal literature. This event occurred outside the us. All information provided is included in this report. Patient information is limited due to confidentiality concerns. Of note, multiple patients were noted in the article; however, a one to one correlation could not be made with unique product serial/lot numbers. The overall baseline gender characteristics is male; the age of the patients was 60 years old. Without a lot number or device serial number, the manufacturing date cannot be determined. Since no device id was provided, it is unknown if this event has been previously reported. A request for additional information will be made and upon receipt a supplemental report will be submitted accordingly. Referenced article: immediate and long-term outcomes of cryoballoon catheter ablation in patients with atrial fibrillation and left common pulmonary vein anatomy. ¿ journal of interventional cardiac electrophysiology. Doi: https://doi. Org/10. 1007/s10840-019-00676-y. If information is provided in the future, a supplemental report will be issued.
 
Event Description
The literature publication reported the following patient complications during the use of a cryoballoon ablation catheter system: there were four patients who experienced phrenic nerve palsy (pnp); all of which resolved ¿spontaneously¿ during the procedure. There were also patients who had vascular access site complications; including hematomas and pseudoaneurysms; all with unknown treatment/resolution. Of note, multiple patients were noted in the article; however, a one to one correlation could not be made with unique product lot numbers. The status/disposition of the cryoablation catheter system is unknown. Further follow up did not yet yield any additional information. No further patient complications have been reported as a result of this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameFLEXCATH ADVANCE STEERABLE SHEATH
Type of DeviceCATHETER, STEERABLE
Manufacturer (Section D)
MEDTRONIC CRYOCATH LP
9000 autoroute transcanadienne
pointe-claire,qc H9R 5 Z8
CA H9R 5Z8
Manufacturer (Section G)
MEDTRONIC CRYOCATH LP
9000 autoroute transcanadienne
pointe-claire,qc H9R 5 Z8
CA H9R 5Z8
Manufacturer Contact
paula bixby
8200 coral sea st ne
mounds view, MN 55112
7635055378
MDR Report Key9592246
MDR Text Key185939851
Report Number3002648230-2020-00039
Device Sequence Number1
Product Code DRA
Combination Product (y/n)N
Reporter Country CodeTU
PMA/PMN Number
K123591
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,l
Reporter Occupation
Type of Report Initial
Report Date 01/15/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/15/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator
Device Model Number4FC12
Device Catalogue Number4FC12
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received01/08/2020
Was Device Evaluated by Manufacturer? No Answer Provided
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 01/15/2020 Patient Sequence Number: 1
-
-