DRÄGERWERK AG & CO. KGAA APOLLO; ANESTHESIA UNITS Back to Search Results
Catalog Number 8606500
Device Problems Intermittent Continuity (1121); Gas Output Problem (1266); Failure to Deliver (2338); No Pressure (2994)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/16/2019
Event Type  malfunction  
Manufacturer Narrative
The investigation has just started; results will be provided in a follow up-report.
 
Event Description
It was reported during a case the device alarmed for "vent failure." there was no patient injury reported.
 
Event Description
Please refer to the initial-report.
 
Manufacturer Narrative
The responsible dräger service engineer could confirm the reported issue during on-site checking and trace it back to the ventilator motor.The entire motor assembly was replaced, consequently.Also the evaluation of the log file confirms an issue with the ventilator (motor) on the date of event.In case the apollo shuts down automatic ventilation, the device will generate an audible alarm and a visible alarm message "ventilator fail" will be displayed.In this case, automatic ventilation is not possible.The user can switch to manual ventilation as described in the instructions for use.Monitoring is still functional.The motor asm has brushes, ball bearing, commutator disk and a spindle which are affected from aging caused by wearing.The kollmorgen motor asm, that was installed in the objected device, has been designed for a durability of 10 years (5 hrs/day, 5 days/week, 52 weeks/year, 13000 hours).The involved motor is approx.12 years old and with the 17,955 hours logged, the device reached 138% of the estimated working hours.The replacement of the affected motor asm by the dräger service engineer has already solved the problem, no patient consequences have reportedly occurred.The number of similar cases, related to the same root cause, is within the expected range of the respective risk assessment and thus accepted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
APOLLO
Type of Device
ANESTHESIA UNITS
Manufacturer (Section D)
DRÄGERWERK AG & CO. KGAA
moislinger allee 53-55
lübeck 23542
GM  23542
MDR Report Key9605500
MDR Text Key175932292
Report Number9611500-2020-00017
Device Sequence Number1
Product Code BSZ
Combination Product (y/n)N
PMA/PMN Number
K042607
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,user f
Type of Report Initial,Followup
Report Date 02/07/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/20/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number8606500
Was Device Available for Evaluation? Yes
Device AgeYR
Date Manufacturer Received12/24/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-