STRYKER INSTRUMENTS-KALAMAZOO SYSTEM 8 SABO SAGITTAL SAW; INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT Back to Search Results
Model Number 4508000000
Device Problem Fluid/Blood Leak (1250)
Patient Problem No Patient Involvement (2645)
Event Date 12/31/2019
Event Type  malfunction  
Manufacturer Narrative
This record is a consolidation of records summarized as a part of the fda voluntary malfunction summary reporting program.Reported events: 3 events were reported for this quarter.Product return status: 3 devices were received.Event confirmation status: 3 reported events were not confirmed.Evaluation results: 3 devices had no problem found.Additional information: 3 devices were not labeled for single-use.3 devices were not reprocessed or reused.
 
Event Description
This report summarizes 3 malfunction events in which the device was reportedly leaking.3 events had no patient involvement; no patient impact.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYSTEM 8 SABO SAGITTAL SAW
Type of Device
INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT
Manufacturer (Section D)
STRYKER INSTRUMENTS-KALAMAZOO
4100 east milham avenue
kalamazoo MI 49001
Manufacturer (Section G)
STRYKER INSTRUMENTS-KALAMAZOO
4100 east milham avenue
kalamazoo MI 49001
Manufacturer Contact
zach baker
4100 east milham avenue
kalamazoo, MI 49001
2693237700
MDR Report Key9637308
MDR Text Key180810821
Report Number0001811755-2020-00329
Device Sequence Number1
Product Code HWE
UDI-Device Identifier07613327304411
UDI-Public07613327304411
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported3
Summary Report (Y/N)Y
Report Source Manufacturer
Source Type company representative
Reporter Occupation Other
Type of Report Initial
Report Date 01/28/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/28/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator No Information
Device Model Number4508000000
Device Catalogue Number4508000000
Was Device Available for Evaluation? No
Date Manufacturer Received12/31/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-