Model Number U125
Device Problems Failure to Capture (1081); High impedance (1291)
Patient Problem Dizziness (2194)
Event Date 09/19/2019
Event Type  malfunction  
Manufacturer Narrative
This product has not been returned to boston scientific, and as a result, laboratory analysis could not be conducted. The associated investigation determined that this device exhibited intermittent impedance measurements with no conclusive evidence of a malfunction or inadequate lead-to-device connection; please refer to the description for more information regarding the specific circumstances of this event.
 
Event Description
It was reported that this patient experienced a near syncopal event and data review noted non capture. However, there appears to be dual pacing spikes at a rate of 100ppm and the patient's underlying rhythm is approximately 40bpm. A boston scientific technical services consultant stated that if there is pacing then there is no capture. The consultant reviewed the data that was collected today. There is variable impedance measurements on all channels with no out of range measurements observed. It appears that signal artifact monitoring (sam) had disabled the respiratory rate trend (rrt); however, there was no stored episode. It was noted that the patient is in chronic atrial fibrillation (af) but atrial sensing is still programmed on. The caller was not able to reproduce any issues during in office testing and reprogramming was performed to unipolar pacing and bipolar sensing. The consultant recommended further evaluation of the system. No adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameVALITUDE CRT-P
Type of DevicePULSE GENERATOR, PACEMAKER, IMPLANTABLE, WITH CARDIAC RESYNCHRONIZATION (CRT-P)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
cashel road
clonmel
EI
Manufacturer Contact
timothy degroot
4100 hamline avenue north
saint paul, MN 55112
6515826168
MDR Report Key9666457
MDR Text Key177766154
Report Number2124215-2020-02483
Device Sequence Number1
Product Code NKE
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P030005/S113
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation
Type of Report Initial
Report Date 02/04/2020
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received02/04/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date05/04/2018
Device Model NumberU125
Device Catalogue NumberU125
Device Lot Number702564
Was Device Available for Evaluation? No
Is the Reporter a Health Professional?
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received12/18/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured05/23/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-