• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ALCON LABORATORIES IRELAND LTD. ACRYSOF IQ TORIC SINGLEPIECE IOL; LENS, INTRAOCULAR, TORIC OPTICS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALCON LABORATORIES IRELAND LTD. ACRYSOF IQ TORIC SINGLEPIECE IOL; LENS, INTRAOCULAR, TORIC OPTICS Back to Search Results
Model Number SN6AT3
Device Problem Defective Component (2292)
Patient Problem No Information (3190)
Event Type  malfunction  
Manufacturer Narrative
Evaluation summary: the product was not returned for analysis.The product history and batch records were reviewed and documentation indicated the product met release criteria.The product investigation could not identify a root cause.There have been no other complaints reported in the lot number.The manufacturer internal reference number is: (b)(4).
 
Event Description
A health professional reported that an intraocular lens (iol) implant was defective.Additional information has been requested.
 
Manufacturer Narrative
The product was returned for analysis and the reported damage was observed.Photo review: the returned pictures show multiple iols.The photo for the serial number reported in this file shows a lens in the iol case.The lens appears to be pressed down into well area of the lens case base and appears to be damaged/deformed.Additional observations were as follows: iol returned positioned incorrectly in the iol case.Solution is dried on the iol.One haptic tip is broken/torn and not returned.The optic is cracked/fractured and scratched/marked-rejectable.We are unable to determine the root cause for the reported complaint "defective".The returned iol shows evidence of possible handling by the customer due to the presence of solution and how it was returned positioned incorrectly in the iol case.In addition to this, all iols are 100% cosmetically inspected as per approved manufacturing procedures and the observed lens damage would not meet our current release criteria.Based on these investigation findings, we are unable to verify that the damage was present when opened and if the iol contributed to the event.All product and batch history records are quality reviewed prior to product release.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACRYSOF IQ TORIC SINGLEPIECE IOL
Type of Device
LENS, INTRAOCULAR, TORIC OPTICS
Manufacturer (Section D)
ALCON LABORATORIES IRELAND LTD.
cork business&technology park
model farm road
cork 00000
EI  00000
MDR Report Key9775340
MDR Text Key184847169
Report Number9612169-2020-00087
Device Sequence Number1
Product Code MJP
Combination Product (y/n)N
PMA/PMN Number
P930014
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Type of Report Initial,Followup
Report Date 06/16/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/02/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date11/30/2022
Device Model NumberSN6AT3
Device Catalogue NumberSN6AT3.310
Device Lot Number21207274
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/05/2020
Date Manufacturer Received06/12/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-