Catalog Number 03P88-25
Device Problem Incorrect, Inadequate or Imprecise Result or Readings (1535)
Patient Problems Anemia (1706); Respiratory Distress (2045); Alteration In Body Temperature (2682)
Event Date 03/05/2020
Event Type  malfunction  
Manufacturer Narrative
Apoc incident # (b)(4).Apoc labeling will be evaluated during the investigation as pertaining to the event.
 
Event Description
On (b)(6) 2020, abbott point of care was contacted by a customer regarding i-stat cg8+ cartridges that yielded suspected discrepant hematocrit result of 47% on a (b)(6) year old female patient with enzyme disorder (fumarase deficiency); impaired regulation of body temperature; chronic respiratory insufficiency; anemia.There was no additional patient information available at the time of this report.Return product is available for investigation.Method: sysmex, date: (b)(6) 2020, collected: 20:44, tested: 21:47, hematocrit: 11.3%.I-stat, (b)(6) 2020, 20:45, 20:48, 47.0%.There are no injuries associated with this event.At this time there is no reason to suspect a malfunction exists.There were multiple attempts for information but to no avail.The reporting decision was based on limited information available that suggests the product was not performing within the variability of the assay.The investigation is underway.
 
Manufacturer Narrative
Apoc incident # (b)(4).The investigation was completed on 04/09/2020.A review of the device history record (dhr) confirmed the cartridge lot met finished goods (fg) release criteria.Retained testing met the acceptance criteria outlined in appendix 1 of q04.01.003 rev.Ae (product complaint level 2 and level 3 investigation procedure).The customer complaint was not reproduced in returned testing.No deficiency has been determined for cg8+ lot w20040.
 
Event Description
Na.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
I-STAT CG8+ CARTRIDGE
Type of Device
CG8+ CARTRIDGE
Manufacturer (Section D)
ABBOTT POINT OF CARE
400 college road
princeton, nj
MDR Report Key9850209
MDR Text Key198917139
Report Number2245578-2020-00037
Device Sequence Number1
Product Code CHL
UDI-Device Identifier10054749000163
UDI-Public10054749000163
Combination Product (y/n)N
PMA/PMN Number
K940918
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Type of Report Initial,Followup
Report Date 04/15/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/18/2020
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date10/08/2020
Device Catalogue Number03P88-25
Device Lot NumberW20040
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/19/2020
Date Manufacturer Received04/09/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Age13 YR
-
-