MEDIVANCE, INC. ¿ 1725056 ARCTICSUN GEL PADS; ARCTIC GEL PADS Back to Search Results
Catalog Number 317-05
Device Problems Device Alarm System (1012); Inaccurate Flow Rate (1249); Insufficient Flow or Under Infusion (2182)
Patient Problems No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete, a supplemental report will be filed.
 
Event Description
It was reported that there was low flow.They were advised to replace the pad on the patient and the alarm ceased.Per additional information received via phone on (b)(6) 2020, the nurse stated they changed the pads and it fixed the problem.Therapy was ongoing with no further issues, and they were to return the pads.
 
Event Description
It was reported that there was low flow.They were advised to replace the pad on the patient and the alarm ceased.Per additional information received via phone on 5mar2020, the nurse stated they changed the pads and it fixed the problem.Therapy was ongoing with no further issues, and they were to return the pads.
 
Manufacturer Narrative
The device was not returned for evaluation.A potential root cause for this failure could be "incorrect machine set up".The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: ¿directions for use 1.Arcticgel¿ pads are only for use with an arctic sun® temperature management system control module.See operators manual for detailed instructions on system use.2.Select the proper number, size and style pad for the patient size and clinical indication.However, the rate of temperature change and potentially the final achievable temperature is affected by pad surface area, patient size, pad placement and water temperature range.Best system performance will be achieved by using the entire pad set (4).If the entire set of pads is not used, the minimum flow rate may not be achieved.3.For patient comfort, the pads may be prewarmed using water temperature control mode (manual) prior to application.4.Place the pads on healthy, clean skin only.Remove any creams or lotions from patient¿s skin before pad application.Remove the release liner from each pad and apply to the appropriate area.The pads may be overlapped or folded adhesive-to-adhesive to achieve proper placement.The pads may be removed and reapplied if necessary.The pad surface must be contacting the skin for optimal energy transfer efficiency.Place pads to allow for full respiratory excursion.5.Attach the pad¿s line connectors to the patient line manifolds.Begin circulating water through the pads using either patient temperature control mode (automatic) or water temperature control mode (manual).If the pads fail to prime or a significant continuous air leak is observed in the pad return line, check connections, then if needed replace the leaking pad.6.Once the pads are primed, assure the flow rate displayed on the control panel is greater than 1.7 liters per minute, which is the minimum flow rate for a full pad kit (4).7.When finished, empty water from pads.Cold temperature increases the adhesiveness of the hydrogel.For ease of removal, leave pads on the patient for approximately 15 minutes to allow the hydrogel to warm.Slowly remove pads from the patient and discard.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARCTICSUN GEL PADS
Type of Device
ARCTIC GEL PADS
Manufacturer (Section D)
MEDIVANCE, INC. ¿ 1725056
321 s taylor ave
louisville CO 80027
MDR Report Key9889403
MDR Text Key186747711
Report Number1018233-2020-02175
Device Sequence Number1
Product Code DWJ
Combination Product (y/n)N
PMA/PMN Number
K142702
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,other
Type of Report Initial,Followup
Report Date 04/23/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/27/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date11/30/2021
Device Catalogue Number317-05
Device Lot NumberNGDYY816
Was Device Available for Evaluation? No
Date Manufacturer Received04/17/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-