Catalog Number 8065752450
Device Problem Mechanics Altered (2984)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Type  malfunction  
Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).
 
Event Description
A surgeon reported the vitrectomy probe did not actuate when was about to performed cutting and aspiration after being inserted into the patient's eye for a procedure.The procedure was completed after replacing the product with another new one.There was no harm to the patient.
 
Manufacturer Narrative
One opened probe was received.The returned sample was visually inspected and found to be non-conforming with orange/brown foreign material on the port face and on the welded cap and clear foreign material on the probe needle.The sample was then functionally tested for actuation, aspiration, and cut and was found to be conforming for all three functional tests.The returned sample was found to be functionally conforming, therefore an actuation failure as described in the complaint was not confirmed and a root cause cannot be determined for the complaint as described by the customer.A review of the device history record traceable to the reported lot number indicates that the product was processed and released according to the product¿s acceptance criteria.No action was taken as the returned probe was functionally conforming.All probes are 100% visually inspected and tested for actuation, aspiration, and cut during manufacturing.Any non-conformance's found are removed from the lot and scrapped.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CONSTELLATION SURGICAL PROCEDURE PAK
Type of Device
GENERAL SURGERY TRAY (KIT)
Manufacturer (Section D)
ALCON RESEARCH, LLC - HOUSTON
9965 buffalo speedway
houston TX 77054
MDR Report Key9940496
MDR Text Key187542266
Report Number1644019-2020-00198
Device Sequence Number1
Product Code LRO
Combination Product (y/n)N
PMA/PMN Number
K880961
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Type of Report Initial,Followup
Report Date 07/15/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/08/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/31/2021
Device Catalogue Number8065752450
Device Lot Number2270918H
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/18/2020
Date Manufacturer Received07/02/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
CONSTELLATION VISION SYSTEM
-
-