|
Class 2 Device Recall HyperHypothermia System |
 |
Date Initiated by Firm |
October 27, 2011 |
Date Posted |
February 07, 2012 |
Recall Status1 |
Terminated 3 on February 26, 2013 |
Recall Number |
Z-0970-2012 |
Recall Event ID |
60721 |
Product Classification |
System, thermal regulating - Product Code DWJ
|
Product |
Hemotherm 48¿C Dual Reservoir Heater/Cooler System, Model Number: 400 and Model Number: 400MR. The 48 o ( Degree) C Hemotherm Dual Reservoir Heater/Cooler I provides a flow of temperature-controlled water to a heat exchanger. The device, in conjunction with a heat exchanger, is used to warm/cool the fluid that enters and exits a heat exchanger. The conductive heat/cool transfer is accomplished through any type of blood oxygenator/heat exchanger unit. The operator of the unit regulates the desired fluid temperature. Frequent observation of the actual blood/fluid temperature and body temperature is required. The Hemotherm does not contact the patient of the fluids; the water being circulated by the Hemotherm is separated from the fluid by the heat exchanger. To active temperatures above 42 Degrees C, the user must follow explicit instructions in to the owner's manual in order to activate the higher setting. Without following the explicit instructions, the device can only operate within the normal maximum temperature range of: 42 degrees C. The Hemotherm can be used with adult and pediatric patients for extracorporeal circulation of the patient's limb, entire body, or a chemo medication lavage of the abdominal area. The Hemotherm 48¿C device system is used to lower/raise the blood/fluid temperature and/or maintain blood/fluid temperature, as required, through conductive heat transfer. The conductive heat transfer is accomplished through any type of Blood Oxygenator/Heat Exchanger unit. This device is intended to hyperthermic treatment of AIDS and cancer patients and associated research. The device can be set to reach an upper temperature of: 48¿C .
|
Code Information |
The recalled Hemotherm Heater/Cooler devices are identified with the following Serial Numbers: 862-8586M, 882-9143M, 882-9163M, 914-9837M, 952-10505M, 973-10918M, 992-11343M, 002-11540M, 003-11585M, 003-11586M, 003-11592M, 003-11600M, 004-11830M, 004-11631M, 014-11807M, 0311-12041M, 042-12250M, 071-12654M, 071-12655M, 073-12117M, 972-10872M, 062-12536M, and 963-10737M. |
Recalling Firm/ Manufacturer |
Cincinnati Sub-Zero Products Inc 12011 Mosteller Rd Cincinnati OH 45241-1528
|
For Additional Information Contact |
Pradeep K. Gupta 513-772-8810
|
Manufacturer Reason for Recall |
The suspect hyper-hypothermia device systems sold to physicians for research and/or the treatment of AIDS and Cancer patients, were not appropriately cleared by the FDA prior to distribution.
|
FDA Determined Cause 2 |
Software design |
Action |
CSZ sent an "URGENT: FIELD ACTION NOTICE" letter dated January 20, 2011 to all affected customers. The letter identifies the product, problem, and actions to be taken by the customers. The letter instructs customers to become familiar with the amended manual page and to get approvals from the Institutional Review Board before further use of the device. Additionally, a response form was enclosed with the letter for customers to complete and return via fax to (513)772-9119. Contact CSZ Service Department at 1-800-989-7373 for questions regarding this notice. |
Quantity in Commerce |
A total of 20 devices were distributed in the U.S. & 3 units were distributed internationally. |
Distribution |
Nationwide Distribution-including the District of Columbia and states of CA, GA, MA, MD, MI, NJ, NY, OH, and UT. |
Total Product Life Cycle |
TPLC Device Report
|
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55.
|
|
|
|