| | Class 2 Device Recall EDAN |  |
| Date Initiated by Firm | October 24, 2025 |
| Date Posted | January 22, 2026 |
| Recall Status1 |
Open3, Classified |
| Recall Number | Z-1144-2026 |
| Recall Event ID |
97879 |
| 510(K)Number | K202892 K233038 |
| Product Classification |
Monitor, physiological, patient (without arrhythmia detection or alarms) - Product Code MWI
|
| Product | Brand Name: EDAN
Product Name: Vital Signs Monitor
Model/Catalog Number: iM3s, iM3As, iM3Bs, iHM3s
Product Description: The iM3s series vital signs monitors including iM3s/iM3As/iM3Bs/iHM3s are intended to be used for measuring, storing, reviewing of, and generating prompts for multiple physiological parameters of adults and pediatrics.
Component: No |
| Code Information |
EDAN Model: iM3s
UDI-DI code: 06944413811171
Serial/Lot Numbers:
262825-H24701480005
262825-H24701480001
262825-H24701480002
262825-H24701480007
262825-H24701480010
262825-H24701480009
262825-H24701480008
262825-H24701480004
262825-H24701480003
262825-H24701480006
262825-H24802410006
262825-H24802410003
262825-H24802410007
262825-H24802410009
262825-H24802410010
262825-H24802410002
262825-H24802410005
262825-H24802410001
262825-H24802410008
262825-H24802410004
261573-M21708880001
261573-M21803610001
261573-M21C04280007
261573-M21C04280003
261573-M21C04280004
261573-M21C04280008
261573-M21C04280002
261573-M21C04280012
261573-M21C04280011
261573-M21C04280010
261573-M21C04280009
261573-M21C04280006
261573-M21C04280013
261573-M21C04280001
261573-M21C04280014
261573-M21C04280005
261573-M21C04280015
261573-M22701100009
261573-M22701100014
261573-M22701100019
261573-M22701100022
261573-M22701100025
261573-M22701100004
261573-M22701100021
261573-M22701100018
261573-M22701100008
261573-M22701100001
261573-M22701100020
261573-M22701100012
261573-M22701100005
261573-M22701100002
261573-M22701100011
261573-M22701100024
261573-M22701100013
261573-M22701100015
261573-M22701100023
261573-M22701100017
261573-M22701100007
261573-M22701100016
261573-M22701100006
261573-M22701100010
261573-M22701100003
262825-M23810180001
262825-M23810180002
261572-M20101720006
263089-H24503150005
263089-H24503150003
263089-H24503150006
263089-H24503150001
263089-H24503150010
263089-H24503150002
263089-H24503150014
263089-H24503150008
263089-H24503150009
263089-H24503150013
263089-H24503150012
263089-H24503150007
263089-H24503150011
263089-H24503150004
263089-H24503150015
262825-H25300480002
262825-H25300480001
263163-H25401870003
263163-H25401870004
263089-H25502070002
263089-H25502070016
263163-H25401870007
263163-H25401870008
263163-H25401870005
263163-H25401870001
263163-H25401870002
263163-H25401870006
263163-H25401870010
262825-H25502470009
263089-H25502070008
263089-H25502070012
263089-H25502070015
263089-H25502070013
263089-H25502070006
263089-H25502070011
263089-H25502070017
263089-H25502070019
263089-H25502070004
263163-H25401870009
263089-H25502070010
263089-H25502070009
263089-H25502070007
263089-H25502070001
263089-H25502070018
263089-H25502070005
263089-H25502070003
262825-H25502470003
262825-H25502470002
262825-H25502470008
262825-H25502470001
262825-H25502470005
262825-H25502470006
262825-H25502470007
263089-H25502070014
262825-H25502470004
262825-H25502470010
263089-H25701330006
263089-H25701330008
263089-H25701330013
263089-H25701330004
263089-H25701330012
263089-H25701330014
263089-H25701330002
263089-H25701330015
263089-H25701330010
263089-H25701330007
263089-H25701330003
263089-H25701330001
263089-H25701330009
263089-H25701330011
263089-H25701330005
|
| FEI Number |
3009499478
|
Recalling Firm/ Manufacturer |
Edan Diagnostics 9833 Pacific Heights Blvd San Diego CA 92121-4707
|
| For Additional Information Contact | Chao Lin 858-7503066 |
Manufacturer Reason for Recall | As a result of receiving an FDA It Has Come to Our Attention Letter (IHCTOA Letter) regarding potential cybersecurity issues with various of the firm device. |
FDA Determined Cause 2 | Device Design |
| Action | On 10/24/2025, the firm emailed notifying customers of a product recall. On 11/06/2025, the firm emailed an "URGENT: MEDICAL DEVICE CORRECTION" Letter to customers informing them of labeling issues involving cybersecurity which arose from a communication from the U.S. Food & Drug Administration.
-First issue involves an inappropriate publicly routable IP address that was used as an example in the user manual for demonstrating user-configurable IP settings and
Second issue involves an inappropriate publicly IP address that was used as the factory default configuration.
Customer are instructed to:
1. Immediately examine their inventory and quarantine product subject to correction.
2. If customers may have further distributed affected product, identify their customers and notify them at once of this product correction. The notification to their customers may be enhanced by including the enclosed URGENT MEDICAL DEVICE CORRECTION.
3. For affected product still in their inventory, place copy of the enclosed Notice Before Use and Corrigenda of User Manual into its package before distribution.
4. For affected product that has been distributed or is in use:
(1) Confirm that they have received and acknowledged Corrigenda of User Manual. Print out a copy, attach to the User Manual.
(2) Confirm the publicly routable IP address 202.114.4.* is NOT used in the User Maintain in the device. If 202.114.4.* is being used, change to appropriate IP settings of device in the Network Setup according to Instruction Instructions for IP Settings Configuration.
5. Complete the attached Acknowledgement and Receipt Form, sign it, and return a scanned copy to the sender of this notification by email.
For questions - Contact:
EDAN Instruments, Inc.
Monday to Friday 09:00-17:00 (UTC+8)
Tel:+86-0755-26898326
EDAN Diagnostics, Inc.
Monday to Friday 09:00-17:00 (PST)
Tel: 1-(858)-750-3066 |
| Quantity in Commerce | 136 |
| Distribution | Worldwide - U.S. Nationwide distribution in the states of CA, KY, PR, FL, CT, IL, PA, RI, NC, NY, LA, TX, MI and the country of Mexico. |
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 The manufacturer has initiated the recall and not all products have been corrected or removed. This record will be updated as the status changes.
|
| 510(K) Database | 510(K)s with Product Code = MWI
|
|
|
|