• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Scientific Publications by FDA Staff

  • Print
  • Share
  • E-mail
-

Search Publications



Fields



Centers











Starting Date


Ending Date


Order by

Entry Details

PLoS One 2017 Jun 29;12(6):e0179939

Automated Interpretation of Influenza Hemagglutination Inhibition (HAI) Assays: Is Plate Tilting Necessary?

Wilson G, Ye Z, Xie H, Vahl S, Dawson E, Rowlen K

Abstract

The hemagglutination inhibition assay (HAI) is widely used to evaluate vaccine-induced antibody responses as well as to antigenically characterize influenza viruses. The results of an HAI assay are based on an endpoint titration where the titers are generally manually interpreted and recorded by a well-trained expert. For serological applications, the lack of standardization in endpoint interpretation and interference from non-specific inhibitors in clinical samples can translate into a high degree of variability in the results. For example, tilting HAI plates at 45-60 degrees to look for a "tear drop pattern" with avian red blood cells is a common practice by many, but not all, research laboratories. In this work, we tested the hypothesis that an automated image analysis algorithm can be used to achieve an accurate and non-subjective interpretation of HAI assays-specifically without the need to tilt plates. In a side-by-side comparison study performed during FDA's biannual serological screening process for influenza viruses, titer calls for more than 2200 serum samples were made by the Cypher One automated hemagglutination analyzer without tilting and by an expert human with tilting. The comparison yielded 95.6% agreement between the expert reader and automated interpretation method (within ± 1 dilution) for the complete dataset. Performance was also evaluated relative to the type of red blood cell (turkey and guinea pig) and influenza strain (12 different viruses). For the subset that utilized guinea pig red blood cells (~44% of the samples), for which no plate tilting was required, the agreement with an expert reader was 97.2%. For the subset that utilized turkey red blood cells (~56% of the samples), for which plate tilting was necessary by the expert reader, the agreement was 94.3%. Overall these results support the postulate that algorithm-based interpretation of a digital record with no plate tilting could replace manual reading for greater consistency in HAI assays.


Category: Journal Article
PubMed ID: #28662088 DOI: 10.1371/journal.pone.0179939
PubMed Central ID: #PMC5491073
Includes FDA Authors from Scientific Area(s): Biologics
Entry Created: 2017-02-06 Entry Last Modified: 2017-07-30
Feedback
-
-