<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet href="https://www.accessdata.fda.gov/spl/stylesheet/spl.xsl" type="text/xsl"?>
<document xmlns="urn:hl7-org:v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:hl7-org:v3 https://www.accessdata.fda.gov/spl/schema/spl.xsd">
   <id root="e90cdadc-4abb-4fbd-9362-7030463d2cd9"/>
   <code code="50577-6" codeSystem="2.16.840.1.113883.6.1" displayName="OTC ANIMAL DRUG LABEL"/>
   <title>
      <content styleCode="bold"/>
   </title>
   <effectiveTime value="20240205"/>
   <setId root="386fc0aa-c4a7-4dff-86bf-d79facb6d6cc"/>
   <versionNumber value="5"/>
   <author>
      <time/>
      <assignedEntity>
         <representedOrganization>
            <id extension="966985624" root="1.3.6.1.4.1.519.1"/>
            <name>Elanco US Inc.</name>
            <assignedEntity>
               <assignedOrganization/>
            </assignedEntity>
         </representedOrganization>
      </assignedEntity>
   </author>
   <component>
      <structuredBody>
         <component>
            <section>
               <id root="b4b48226-76d8-4195-853e-0b6b7b1c4f3c"/>
               <code code="48780-1" codeSystem="2.16.840.1.113883.6.1" displayName="SPL product data elements section"/>
               <effectiveTime value="20240205"/>
               <subject>
                  <manufacturedProduct>
                     <manufacturedProduct>
                        <code code="58198-0327" codeSystem="2.16.840.1.113883.6.69"/>
                        <name>Compudose</name>
                        <formCode code="C42942" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="IMPLANT"/>
                        <asEntityWithGeneric>
                           <genericMedicine>
                              <name>estradiol</name>
                           </genericMedicine>
                        </asEntityWithGeneric>
                        <ingredient classCode="ACTIB">
                           <quantity>
                              <numerator unit="mg" value="25.7"/>
                              <denominator unit="1" value="1"/>
                           </quantity>
                           <ingredientSubstance>
                              <code code="4TI98Z838E" codeSystem="2.16.840.1.113883.4.9"/>
                              <name>estradiol</name>
                              <activeMoiety>
                                 <activeMoiety>
                                    <code code="4TI98Z838E" codeSystem="2.16.840.1.113883.4.9"/>
                                    <name>estradiol</name>
                                 </activeMoiety>
                              </activeMoiety>
                           </ingredientSubstance>
                        </ingredient>
                        <asContent>
                           <quantity>
                              <numerator unit="1" value="20"/>
                              <denominator value="1"/>
                           </quantity>
                           <containerPackagedProduct>
                              <code/>
                              <formCode code="C43183" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="CARTRIDGE"/>
                              <asContent>
                                 <quantity>
                                    <numerator unit="1" value="5"/>
                                    <denominator value="1"/>
                                 </quantity>
                                 <containerPackagedProduct>
                                    <code code="58198-0327-1" codeSystem="2.16.840.1.113883.6.69"/>
                                    <formCode code="C43182" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="CARTON"/>
                                 </containerPackagedProduct>
                              </asContent>
                           </containerPackagedProduct>
                        </asContent>
                     </manufacturedProduct>
                     <subjectOf>
                        <approval>
                           <id extension="NADA118123" root="2.16.840.1.113883.3.150"/>
                           <code code="C73593" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="NADA"/>
                           <author>
                              <territorialAuthority>
                                 <territory>
                                    <code code="USA" codeSystem="2.16.840.1.113883.5.28"/>
                                 </territory>
                              </territorialAuthority>
                           </author>
                        </approval>
                     </subjectOf>
                     <subjectOf>
                        <marketingAct>
                           <code code="C53292" codeSystem="2.16.840.1.113883.3.26.1.1"/>
                           <statusCode code="active"/>
                           <effectiveTime>
                              <low value="19820312"/>
                           </effectiveTime>
                        </marketingAct>
                     </subjectOf>
                     <consumedIn>
                        <substanceAdministration>
                           <routeCode code="C38299" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="SUBCUTANEOUS"/>
                        </substanceAdministration>
                     </consumedIn>
                  </manufacturedProduct>
               </subject>
            </section>
         </component>
         <component>
            <section ID="s1">
               <id root="8788d336-9bbe-441b-ba6f-ee736b57caaa"/>
               <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
               <text>
                  <paragraph>
                     <content styleCode="bold">Elanco</content>™ </paragraph>
                  <paragraph>AH0948 </paragraph>
                  <paragraph>
                     <content styleCode="bold">Compudose</content>™ </paragraph>
                  <paragraph>
                     <content styleCode="bold">(estradiol extended-release implants)</content>
                  </paragraph>
                  <paragraph>
                     <content styleCode="bold">Each extended-release implant consists of 25.7 mg estradiol</content>
                  </paragraph>
               </text>
               <effectiveTime value="20240205"/>
            </section>
         </component>
         <component>
            <section ID="s2">
               <id root="3395c19d-c817-4853-99c3-a2e1d9dec8b6"/>
               <code code="34089-3" codeSystem="2.16.840.1.113883.6.1" displayName="DESCRIPTION SECTION"/>
               <title>DESCRIPTION: </title>
               <text>
                  <paragraph>Each Compudose (estradiol extended-release implant) silicone rubber implant contains 25.7 mg estradiol and is coated with sodium bicarbonate. </paragraph>
                  <paragraph>For subcutaneous ear implantation only. </paragraph>
               </text>
               <effectiveTime value="20240205"/>
            </section>
         </component>
         <component>
            <section ID="s3">
               <id root="10eeaf92-a3bd-4ea5-825b-9fec21355c8f"/>
               <code code="34067-9" codeSystem="2.16.840.1.113883.6.1" displayName="INDICATIONS &amp; USAGE SECTION"/>
               <title>INDICATIONS FOR USE: </title>
               <text>
                  <list listType="unordered">
                     <item>
                        <caption>•</caption>For increased rate of weight gain for up to 200 days in beef steer calves 2 months of age and older.</item>
                     <item>
                        <caption>•</caption>For increased rate of weight gain for up to 200 days in growing beef steers on pasture (stocker, feeder, and slaughter).</item>
                     <item>
                        <caption>•</caption>For increased rate of weight gain and improved feed efficiency for up to 200 days in growing beef steers and heifers fed in confinement for slaughter.</item>
                     <item>
                        <caption>•</caption>This implant is not approved for repeated implantation (reimplantation) with this or any other cattle ear implant within each separate production phase:<list listType="unordered">
                           <item>
                              <caption>•</caption>Beef steer calves 2 months of age and older</item>
                           <item>
                              <caption>•</caption>Growing beef steers on pasture (stocker, feeder, and slaughter)</item>
                           <item>
                              <caption>•</caption>Growing beef steers and heifers fed in confinement for slaughter</item>
                        </list>
                     </item>
                  </list>
                  <paragraph>Safety and effectiveness following reimplantation have not been evaluated.</paragraph>
                  <paragraph>Do not use in beef calves less than 2 months of age, dairy calves, and veal calves because effectiveness and safety have not been established.</paragraph>
                  <paragraph>Do not use in animals intended for subsequent breeding or in dairy cows.</paragraph>
               </text>
               <effectiveTime value="20230327"/>
            </section>
         </component>
         <component>
            <section ID="s5">
               <id root="8915e4d7-3645-42b5-937d-23a27a7d0e98"/>
               <code code="34068-7" codeSystem="2.16.840.1.113883.6.1" displayName="DOSAGE &amp; ADMINISTRATION SECTION"/>
               <title>DIRECTIONS: </title>
               <text>
                  <paragraph>Insert one implant under the skin of the ear as directed in the detailed "DIRECTIONS FOR IMPLANTATION" below.</paragraph>
                  <table styleCode="Noautorules" width="100%">
                     <col width="100%"/>
                     <tbody>
                        <tr>
                           <td align="center" valign="middle">
                              <paragraph>
                                 <content styleCode="bold">WITHDRAWAL PERIODS AND RESIDUE WARNINGS</content>
                              </paragraph>
                              <paragraph>
                                 <content styleCode="bold">No withdrawal period is required when used according to labeling. Do not use in beef calves less than 2 months of age, dairy calves, and veal calves. A withdrawal period has not been established for this product in pre-ruminating calves. Do not use in dairy cows or in animals intended for subsequent breeding. Use in these cattle may cause drug residues in milk and/or in calves born to these cows. Implant pellets subcutaneously in ear only. Any other location is a violation of Federal law. Do not attempt salvage of implanted site for human or animal food.</content>
                              </paragraph>
                           </td>
                        </tr>
                     </tbody>
                  </table>
               </text>
               <effectiveTime value="20230327"/>
            </section>
         </component>
         <component>
            <section ID="ID_f5ed6c6a-1497-4b2b-8a01-9b595bc31aa0">
               <id root="96815ecf-9df3-4994-98af-ab57f7a0befe"/>
               <code code="54433-8" codeSystem="2.16.840.1.113883.6.1" displayName="USER SAFETY WARNINGS SECTION"/>
               <title>USER SAFETY WARNINGS: </title>
               <text>
                  <paragraph>
                     <content styleCode="bold">Not for use in humans.</content>
                  </paragraph>
                  <paragraph>
                     <content styleCode="bold">Keep out of reach of children.</content>
                  </paragraph>
               </text>
               <effectiveTime value="20230327"/>
            </section>
         </component>
         <component>
            <section ID="s7">
               <id root="51f0e39a-c004-4337-8b89-f7c25ade48c8"/>
               <code code="34071-1" codeSystem="2.16.840.1.113883.6.1" displayName="WARNINGS SECTION"/>
               <title>ANIMAL SAFETY WARNINGS: </title>
               <text>
                  <paragraph>Increased sexual activity (bulling, riding and excitability) has been reported in animals implanted with Compudose. Implanted animals should be observed for such signs particularly during the first few days after implanting and animals being excessively ridden (bullers) should be removed to prevent physical injury.</paragraph>
                  <paragraph>Vaginal and rectal prolapse have been reported in heifers implanted with Compudose.</paragraph>
                  <paragraph>Udder development, swollen or enlarged vulva and high tailheads may be observed in implanted heifers.</paragraph>
               </text>
               <effectiveTime value="20240205"/>
            </section>
         </component>
         <component>
            <section ID="s9">
               <id root="5283e5b5-059d-455c-9e5d-4be974140370"/>
               <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
               <title>DIRECTIONS FOR IMPLANTATION: </title>
               <text>
                  <paragraph>A Compudose (estradiol extended-release implant) or Encore (estradiol extended-release implant) Implanter must be used to implant cattle.</paragraph>
                  <renderMultiMedia ID="id266816926" referencedObject="A1712F88-88F1-43A4-B64E-A4C3AE211705">
                     <caption>COMPUDOSE/ENCORE IMPLANTER</caption>
                  </renderMultiMedia>
                  <paragraph>Insert one implant under the skin of the ear. </paragraph>
                  <list listType="ordered">
                     <item>
                        <caption>1.</caption>Confine animal in a squeeze chute. </item>
                     <item>
                        <caption>2.</caption>To reduce the possibility of infection and resulting implant loss, hygienic and antiseptic procedures should be followed during implantation. The ear should be clean and dry. The skin should be cleansed with a suitable antiseptic soap and dried prior to implanting. This is particularly important if the ears are contaminated with urine or feces. </item>
                     <item>
                        <caption>3.</caption>To load the Compudose/Encore™ Implanter remove the cartridge from the package, release the latch on the magazine, open and insert the cartridge. (<linkHtml href="#id2140221906">Figure 1</linkHtml>)<br/>Close the magazine and latch. Advance the cartridge to the next implant by inserting the thumb into the magazine opening and turning the cartridge to the next stop.<br/>Use a sharp needle. The needle should be cleaned and sterilized between each injection by wiping the exterior with a sponge, cloth, or gauze saturated with an appropriate disinfectant.<paragraph>
                           <renderMultiMedia ID="id2140221906" referencedObject="BDE01168-929F-4315-B1A1-BBEB3BDC095B">
                              <caption>Figure 1</caption>
                           </renderMultiMedia>
                        </paragraph>
                     </item>
                  </list>
                  <list listType="ordered">
                     <item>
                        <caption>4.</caption>The implant should be deposited under the skin on the back side of the middle third of the ear. It should be placed between the skin and cartilage, avoiding major blood vessels.<br/>Grasping the tip of the ear with one hand and the implanter in the other, penetrate the skin in the outer third of the ear. (see <linkHtml href="#id837042450">Figure 2</linkHtml>)</item>
                  </list>
                  <renderMultiMedia ID="id837042450" referencedObject="F6E50241-ABF8-4C9E-AA11-C991FF15B7C8">
                     <caption>Figure 2</caption>
                  </renderMultiMedia>
                  <list listType="unordered">
                     <item>
                        <caption> </caption>
                        <content styleCode="bold">IMPORTANT:</content> Do not penetrate cartilage.</item>
                  </list>
                  <list listType="ordered">
                     <item>
                        <caption>5.</caption>Upon penetration, the needle should be fully inserted (<linkHtml href="#id-1390255031">Figure 3</linkHtml>) between the skin and cartilage, avoiding major blood vessels. Full insertion of the needle is important to maximize implant retention. </item>
                  </list>
                  <renderMultiMedia ID="id-1390255031" referencedObject="ID_3807e924-c730-4996-974d-77ca6795d9cf">
                     <caption>Figure 3</caption>
                  </renderMultiMedia>
                  <list listType="ordered">
                     <item>
                        <caption>6.</caption>Pull the needle back as the implant is being deposited by squeezing the lever on the implanter grip. <linkHtml href="#id-1574662247">Figure 4</linkHtml> shows the implant in proper position in the middle third of the ear where the skin is tight. </item>
                     <item>
                        <caption>7.</caption>Periodically remove the needle from the device and wash it in water. Before reusing, the needle should be disinfected and allowed to dry after shaking vigorously to remove excess water or disinfectant. <paragraph>
                           <content styleCode="bold">Proper Position</content>
                        </paragraph>
                     </item>
                  </list>
                  <content styleCode="bold">
                     <renderMultiMedia ID="id-1574662247" referencedObject="B9A7F66E-BE6F-47A4-B7FA-1F0D593AAE80">
                        <caption>Figure 4</caption>
                     </renderMultiMedia>
                  </content>
                  <paragraph>
                     <content styleCode="bold">To maximize implant retention: </content>
                  </paragraph>
                  <list listType="ordered">
                     <item>
                        <caption>A.</caption>Fully insert the needle. </item>
                     <item>
                        <caption>B.</caption>Deposit the implant in the middle third of the ear where the skin is tight. </item>
                     <item>
                        <caption>C.</caption>Do not deposit the implant where the skin is loose in the third of the ear closest to the head. </item>
                  </list>
                  <paragraph>The needle has been scientifically designed to maximize retention. When it becomes dull, use a new needle. If the needle is resharpened, sharpen only the point. </paragraph>
                  <paragraph>Failure to follow antiseptic implanting procedures, particularly when the ears are contaminated with fecal material, may result in infection and excessive implant loss. Implanting cattle during wet weather may increase infection and implant loss. </paragraph>
                  <paragraph>Carefully check the ears for implant loss approximately 4 weeks after implantation. If loss occurs, reimplant using recommended procedures. </paragraph>
               </text>
               <effectiveTime value="20240205"/>
               <component>
                  <observationMedia ID="A1712F88-88F1-43A4-B64E-A4C3AE211705">
                     <text>Figure</text>
                     <value mediaType="image/jpeg" xsi:type="ED">
                        <reference value="com0l-0002-01.jpg"/>
                     </value>
                  </observationMedia>
               </component>
               <component>
                  <observationMedia ID="BDE01168-929F-4315-B1A1-BBEB3BDC095B">
                     <text>Figure 1</text>
                     <value mediaType="image/jpeg" xsi:type="ED">
                        <reference value="com0l-0002-02.jpg"/>
                     </value>
                  </observationMedia>
               </component>
               <component>
                  <observationMedia ID="F6E50241-ABF8-4C9E-AA11-C991FF15B7C8">
                     <text>Figure 2</text>
                     <value mediaType="image/jpeg" xsi:type="ED">
                        <reference value="com0l-0002-03.jpg"/>
                     </value>
                  </observationMedia>
               </component>
               <component>
                  <observationMedia ID="ID_3807e924-c730-4996-974d-77ca6795d9cf">
                     <text>Figure 3</text>
                     <value mediaType="image/jpeg" xsi:type="ED">
                        <reference value="com0l-0002-04.jpg"/>
                     </value>
                  </observationMedia>
               </component>
               <component>
                  <observationMedia ID="B9A7F66E-BE6F-47A4-B7FA-1F0D593AAE80">
                     <text>Figure 4</text>
                     <value mediaType="image/jpeg" xsi:type="ED">
                        <reference value="com0l-0002-05.jpg"/>
                     </value>
                  </observationMedia>
               </component>
            </section>
         </component>
         <component>
            <section ID="s11">
               <id root="61ac52fe-89e7-4687-94cc-ba27ed3df39f"/>
               <code code="34069-5" codeSystem="2.16.840.1.113883.6.1" displayName="HOW SUPPLIED SECTION"/>
               <title>How Supplied: </title>
               <text>
                  <paragraph>Compudose Implants are supplied in cartridges of 20 implants each. </paragraph>
                  <paragraph>
                     <content styleCode="bold">Storage Conditions</content>
                  </paragraph>
                  <paragraph>Store at 15 to 25°C (59-77°F). Do not refrigerate or freeze.</paragraph>
                  <paragraph>
                     <content styleCode="bold">Approved by FDA under NADA # 118-123 </content>
                  </paragraph>
                  <paragraph>
                     <content styleCode="bold">Manufactured by a non-sterilizing process.</content>
                  </paragraph>
                  <paragraph>
                     <content styleCode="bold">RESTRICTED DRUG (CALIFORNIA) – USE ONLY AS DIRECTED</content>
                  </paragraph>
                  <paragraph>Compudose, Encore, Elanco and the diagonal bar logo are trademarks of Elanco or its affiliates.</paragraph>
                  <paragraph>© 2023 Elanco or its affiliates</paragraph>
                  <paragraph>Distributed by Elanco US, Inc.<br/>Greenfield, IN 46140, USA </paragraph>
                  <paragraph>Product of Germany </paragraph>
                  <paragraph>To report side effects, for technical assistance or to obtain a copy of the Safety Data Sheet (SDS), contact Elanco US Inc., at 1-888-545-5973. For additional information about reporting side effects for animal drugs, contact FDA at 1-888-FDA-VETS or <linkHtml href="https://www.fda.gov/animal-veterinary/report-problem/how-report-animal-drug-and-device-side-effects-and-product-problems">http://www.fda.gov/reportanimalae</linkHtml>.</paragraph>
                  <paragraph>May 2023                       PA104038X</paragraph>
               </text>
               <effectiveTime value="20240205"/>
            </section>
         </component>
         <component>
            <section ID="s12">
               <id root="f7f49a1b-6af3-4957-88b1-06a20cb44585"/>
               <code code="51945-4" codeSystem="2.16.840.1.113883.6.1" displayName="PACKAGE LABEL.PRINCIPAL DISPLAY PANEL"/>
               <title>Principal Display Panel - Compudose Carton Label </title>
               <text>
                  <paragraph>
                     <content styleCode="bold">Elanco™</content>
                  </paragraph>
                  <paragraph>AH0948</paragraph>
                  <paragraph>
                     <content styleCode="bold">Compudose™</content>
                  </paragraph>
                  <paragraph>™ </paragraph>
                  <paragraph>(<content styleCode="bold">estradiol extended-release implants</content>) </paragraph>
                  <paragraph>
                     <content styleCode="bold">Each extended-release implant consists of 25.7 mg estradiol</content>
                  </paragraph>
                  <paragraph>
                     <content styleCode="bold">Net contents:<br/>5 CARTRIDGES <br/>Each Cartridge <br/>contains 20 implants <br/>(100 Implants total)</content>
                  </paragraph>
                  <content styleCode="bold">
                     <renderMultiMedia ID="id782073445" referencedObject="ID_1231e823-2f5b-4df3-8718-a594887b42df"/>
                  </content>
               </text>
               <effectiveTime value="20240205"/>
               <component>
                  <observationMedia ID="ID_1231e823-2f5b-4df3-8718-a594887b42df">
                     <text>Principal Display Panel - Compudose Carton Label</text>
                     <value mediaType="image/jpeg" xsi:type="ED">
                        <reference value="com0l-0002-06.jpg"/>
                     </value>
                  </observationMedia>
               </component>
            </section>
         </component>
         <component>
            <section ID="s13">
               <id root="86b10e37-f4da-44fc-b3b4-22e985a8bb2f"/>
               <code code="51945-4" codeSystem="2.16.840.1.113883.6.1" displayName="PACKAGE LABEL.PRINCIPAL DISPLAY PANEL"/>
               <title>Principal Display Panel - Compudose Cartridge Label </title>
               <text>
                  <paragraph>AH0948 </paragraph>
                  <paragraph>
                     <content styleCode="bold">Elanco™</content>
                  </paragraph>
                  <paragraph>
                     <content styleCode="bold">Compudose™</content>
                  </paragraph>
                  <paragraph>™ </paragraph>
                  <paragraph>
                     <content styleCode="bold">(estradiol extended-release implants)</content>
                  </paragraph>
                  <paragraph>
                     <content styleCode="bold">Each implant consists of 25.7 mg estradiol</content>
                  </paragraph>
                  <paragraph>
                     <content styleCode="bold">20 IMPLANTS</content>
                  </paragraph>
                  <renderMultiMedia ID="id-1209561277" referencedObject="ID_0d575e71-06dd-49cf-9b03-2c551e072ff5"/>
               </text>
               <effectiveTime value="20240205"/>
               <component>
                  <observationMedia ID="ID_0d575e71-06dd-49cf-9b03-2c551e072ff5">
                     <text>Principal Display Panel - Compudose Cartridge Label</text>
                     <value mediaType="image/jpeg" xsi:type="ED">
                        <reference value="com0l-0002-07.jpg"/>
                     </value>
                  </observationMedia>
               </component>
            </section>
         </component>
      </structuredBody>
   </component>
</document>