• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V. BD CONNECTA STOPCOCK

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V. BD CONNECTA STOPCOCK Back to Search Results
Catalog Number 394945
Device Problems Infusion or Flow Problem (2964); Material Twisted/Bent (2981)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 05/06/2020
Event Type  malfunction  
Manufacturer Narrative
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.(b)(4).
 
Event Description
It was reported that the bd connecta¿ stopcock tubing was kinked during use and prevented drug flow into the patient.This occurred on 25 separate occasions, but the dates and/or patient information are unknown.The following information was provided by the initial reporter: "the customer informs that several eaches in lot 9337119b have the same issue with the connecta stopcock with extension set; the tube is so bent that it cannot be straightened and therefore prevents the flow of drugs into the patient.This problem has occured several times and customer considers this a patient safety issue.Last year they had the same issue for several months with the same product.".
 
Event Description
It was reported that the bd connecta¿ stopcock tubing was kinked during use and prevented drug flow into the patient.This occurred on 25 separate occasions, but the dates and/or patient information are unknown.The following information was provided by the initial reporter: "the customer informs that several eaches in lot 9337119b have the same issue with the connecta stopcock with extension set; the tube is so bent that it cannot be straightened and therefore prevents the flow of drugs into the patient.This problem has occured several times and customer considers this a patient safety issue.Last year they had the same issue for several months with the same product.".
 
Manufacturer Narrative
The following fields were updated due to additional information: d10.Device available for eval?: yes.D10.Returned to manufacturer on: 6/4/2020.H6.Investigation: a device history record review was performed for provided lot number 9337119.The review did not reveal any detected quality issues during the production process that could have contributed to this reported incident and all inspections were found to be within specification.To aid in the investigation of this incident, one unused sample was received for evaluation by our quality engineer team.Through examination of the sample, the tubing was observed kinked.The tubing was measured and the length was found to be within specifications; however, the length was close to the lower specification limit which could have contributed to the observed defect.In response to this incident, a quality alert has been issued to increase the awareness of this potential defect on the production floor.H3 other text : see h10.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD CONNECTA STOPCOCK
Type of Device
STOPCOCK
Manufacturer (Section D)
BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V.
periferico luis donaldo
colosio no. 579
nogales
MX 
MDR Report Key10105716
MDR Text Key204773758
Report Number9610847-2020-00164
Device Sequence Number1
Product Code FMG
Combination Product (y/n)N
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,other,user facility
Type of Report Initial,Followup
Report Date 07/10/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date11/30/2022
Device Catalogue Number394945
Device Lot Number9337119
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/04/2020
Initial Date Manufacturer Received 05/11/2020
Initial Date FDA Received06/01/2020
Supplement Dates Manufacturer Received05/11/2020
Supplement Dates FDA Received07/10/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Other;
-
-