Model Number 7300TFX
Device Problems Gradient Increase (1270); Incomplete Coaptation (2507); Appropriate Term/Code Not Available (3191)
Patient Problems Mitral Regurgitation (1964); Mitral Valve Stenosis (1965); Regurgitation (2259); Stenosis (2263)
Event Date 06/11/2020
Event Type  Injury  
Manufacturer Narrative
Additional manufacturer narrative: the device was not returned to edwards for evaluation as it remains implanted.The device history record (dhr) was reviewed and shows that this device met all manufacturing specifications for product release prior to distribution.No issues were identified that would have impacted this event.Bioprosthetic tissue valves can deteriorate with time and eventually fail contributing to regurgitation and/or stenosis.There can be a number of potential known and unknown patient related contributing factors.Structural valve deterioration (svd), a common reason for bioprosthesis explant or reoperation, encompasses multiple failure modes, including calcific and non-calcific degeneration, dehiscence, cusp thickening or fibrosis, or a combination of these.Such failure modes, occurring singularly or concomitantly, may contribute to stenosis and/or regurgitation.Alternatively, nonstructural dysfunction (nsvd) may also play a role in the development of valvular stenosis.A manufacturing related issue was not identified.A definitive root cause could not be determined; however, it is likely that patient related factors and the progression of the underlying valvular disease pathology contributed to the event.If additional information is received a supplemental mdr will be submitted.Edwards lifesciences will continue to monitor all reported events.No further actions are required at this time.
 
Event Description
It was reported that a patient with a 25mm valve implanted for six years, four months underwent a valve-in-valve procedure due to stenosis and regurgitation.A 26mm valve was implanted.
 
Event Description
It was reported that a patient with a 25mm valve implanted for six years, four months underwent a valve-in-valve procedure due to severe stenosis and regurgitation.A 26mm 9750tfx valve was successfully implanted.Post-procedure tee demonstrated good positioning and no significant paravalvular leaks and estimated mean gradient of 5 mmhg.The patient tolerated the procedure well without complications.The patient was discharged on pod #1.
 
Manufacturer Narrative
H10: additional manufacturer narrative: updated sections b5, b7, and h6 (method).
 
Manufacturer Narrative
Corrected data: f10, h6.Reference capa-20-00141.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL EASE PERICARDIAL BIOPROSTHESES
Type of Device
REPLACEMENT HEART VALVE
Manufacturer (Section D)
EDWARDS LIFESCIENCES
1 edwards way
irvine CA 92614
MDR Report Key10235102
MDR Text Key200004498
Report Number2015691-2020-12425
Device Sequence Number1
Product Code DYE
Combination Product (y/n)N
PMA/PMN Number
P860057/S068
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup,Followup
Report Date 06/11/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/06/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date11/06/2017
Device Model Number7300TFX
Was Device Available for Evaluation? No
Date Manufacturer Received07/23/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Life Threatening; Required Intervention;
Patient Age75 YR
-
-