BIOSENSE WEBSTER INC THERMOCOOL SMART TOUCH SF BI-DIRECTIONAL NAVIGATION CATHETER; CARDIAC ABLATION PERCUTANEOUS CATHETER Back to Search Results
Model Number D134805
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Cardiac Tamponade (2226); No Code Available (3191)
Event Date 06/18/2020
Event Type  Injury  
Manufacturer Narrative
(b)(4).Device evaluation summary: the device was visually inspected and it was found in good conditions.The magnetic, temperature and force features were tested and no issues were observed.In addition, the catheter was deflecting and irrigating correctly.No malfunctions were observed during the product analysis.A manufacturing record evaluation was performed and no internal actions related to the reported complaint were identified.The catheter passed all specifications.The root cause of the adverse event remains unknown.The instructions for use states that careful catheter manipulation must be performed to avoid cardiac damage, perforation or tamponade.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's reference number: (b)(4).
 
Event Description
It was reported that an (b)(6)-year-old female patient ((b)(6) lbs) underwent a right sided atrial flutter (r-afl) ablation procedure with a thermocool® smart touch® sf bi-directional navigation catheter and suffered cardiac tamponade requiring pericardiocentesis and surgical intervention.During the ablation, a steam pop on the junction of the inferior vena cava and right atrium occurred.The patient¿s blood pressure dropped, and cardiac tamponade was confirmed by ultrasound.Interventional cardiologist was called in to place a pericardiocentesis drain which was successfully placed, but persistent filling of pericardium required surgical intervention.Ct surgeon was called in to perform sternotomy and repair the perforation directly.Patient¿s condition improved.Extended hospitalization was required due to the adverse event and extent of surgical intervention.The patient was transferred to the intensive care unit (icu) for recovery and observation.Physician¿s opinion regarding the cause of the adverse event is that it was patient condition related.Transseptal puncture was performed with an abbott/st jude medical ¿ brk-1 (71cm) and brk-1 (98cm).Flow rate was at default setting of 8ml/min for smart touch sf catheter.No error messages were observed on any biosense webster, inc.Equipment.The force visualization features used included graph, dashboard and vector.The parameters for stability used with the visitag module were range: 2.5mm time: 3s, fot: 25% min 3g and tag size: 3mm.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
THERMOCOOL SMART TOUCH SF BI-DIRECTIONAL NAVIGATION CATHETER
Type of Device
CARDIAC ABLATION PERCUTANEOUS CATHETER
Manufacturer (Section D)
BIOSENSE WEBSTER INC
33 technology drive
irvine CA 92618
Manufacturer (Section G)
BIOSENSE WEBSTER INC (JUAREZ)
circuito interior norte
1820parque industrial salvacar
juarez 32599
MX   32599
Manufacturer Contact
gabriel alfageme
31 technology drive
irvine, CA 92618
949789-868
MDR Report Key10286667
MDR Text Key199271441
Report Number2029046-2020-00887
Device Sequence Number1
Product Code LPB
UDI-Device Identifier10846835010183
UDI-Public10846835010183
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P030031
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Physician
Type of Report Initial
Report Date 06/18/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date12/09/2020
Device Model NumberD134805
Device Catalogue NumberD134805
Device Lot Number30324367M
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/06/2020
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 06/18/2020
Initial Date FDA Received07/16/2020
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured12/10/2019
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Life Threatening; Required Intervention;
Patient Age84 YR
Patient Weight59
-
-