INTEGRA LIFESCIENCES MANSFIELD CODMAN DISPOS PERFORATOR; DISPOSABLE PERFORATORS Back to Search Results
Catalog Number 261221
Device Problem Mechanical Problem (1384)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 01/17/2020
Event Type  malfunction  
Manufacturer Narrative
Attempts are being made to obtain additional information.Upon completion of the investigation, a follow-up report will be submitted.
 
Event Description
On (b)(6) 2020, during a craniotomy for a hematoma removal, the perforator failed to disengage during the perforation of the 8th burrhole.There was no problem from 1st to 7th perforations.The perforator stopped at the plastic sleeve.It was planned to make 8th holes, so the perforator was removed, and the procedure was continued.The event led to 30 minute surgical delay with no consequences for the patient.There was no damage on dura mater because the placed perforator was on the hematoma.The patient recovered.Eg1 drill system was used with the perforator.
 
Manufacturer Narrative
Complaint sample was not returned to codman and lot number information has not been provided; therefore, an evaluation of the device could not be performed, and manufacturing records could not be reviewed.The cause(s) of the difficulty reported by the customer could not be determined.If additional relevant information becomes available in the future, this complaint will be reopened, and the respective evaluation performed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CODMAN DISPOS PERFORATOR
Type of Device
DISPOSABLE PERFORATORS
Manufacturer (Section D)
INTEGRA LIFESCIENCES MANSFIELD
11 cabot boulevard
11 cabot boulevard
mansfield MA 02048
MDR Report Key10293010
MDR Text Key203498611
Report Number1226348-2020-00448
Device Sequence Number1
Product Code HBF
Combination Product (y/n)N
PMA/PMN Number
K791101
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 01/20/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/17/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number261221
Was Device Available for Evaluation? No
Date Manufacturer Received02/12/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-